Command Syntax
[SOURce:]CURRent:PROTect:LEVel
Description
This command sets the programmable current trip level for all phases.
The value set cannot exceed the maximum current capability of the
power source as returned by the “
[SOURce:]CURRent:LIMit#:MAX?”
command.
If the load current exceeds the current trip set point, the source will
turn off its output after the “
CURRent:PROTect:TOUT
” delay time outs
and generate a fault message.
Parameters
0.00 – MAX
Parameter Format
<nr2>
Example
CURR:PROT:LEV 24.0000
Query Format
[SOURce:]CURRent:PROTect:LEVel?
Returned Data Format
<nr2>
Query Example
CURR:PROT:LEV?
24.0000
8.7.5
Current Protection Programming Commands
Command Syntax
[SOURce:]CURRent:LIMit# <nr2>
Description
This command sets the programmable RMS or DC current limit for the
selected phase #
Parameters
Phase, Current
Parameter Format
<nr1>, <nr2>
Example
SOUR:CURR:LIM1 41.67
Query Format
[SOURce:]CURRent:LIMit#?
Returned Data Format
<nr2>
Query Example
CURR:LIM1?
41.67
Command Syntax
[SOURce:]CURRent:LIMit:AUTO <b>
Description
This command enables or disables the Auto Current limit mode. When
enables, the current limit will adjust when selecting the low voltage
range.
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
SOUR:CURR:LIM:AUTO 0
Query Format
[SOURce:]CURRent:LIMit:AUTO?
Returned Data Format
<b>
Query Example
CURR:LIM:AUTO?
0
Query Format
[SOURce:]CURRent:LIMit#:DEFault?
Description
This command returns the default current liimt setting at power up for
the referenced phase.
Returned Data Format
<nr2>
Query Example
CURR:LIM:DEF1?
41.67