AFX SERIES® OPERATION MANUAL
SECTION 8: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 147 of 274
Command Syntax
MEASure:LOGger:TIMEstamp <cr>
Description
Sets the time stamp format that will be attached to every
measurement record in the measurement log file.
Parameters
< DATE | 0 | TIME | 1 | ALL | 2 >
Parameter Format
<cr>
Example
MEAS:LOG:TIME ALL
Query Format
MEASure:LOGger:TIMEstamp?
Returned Data Format
<nr1>
Query Example
MEAS:LOG:TIME?
2
8.5
Output Control Commands
The output command subsystem is used to control the output state of the power source.
The following measurement commands are supported.
Command Syntax
OUTPut:FAST <b>
Description
Enable or disable fast energy savings startup mode (STANDBY mode)
when output is closed. This mode does not completely shut down all
inverters for energy savings while the output is off. This allows near
immediate application of output to the load when the output
command is received. When disabled, there is delay of 2.2 seconds to
allow all power stages to start up and settle in.
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
OUTP:FAST ON
Query Format
OUTPut:FAST?
Returned Data Format
<b>
Query Example
OUTP:FAST?
1
Summary of Contents for 3120AFX
Page 273: ......