background image

operating 

manual

PLS

1

P A C I F I C   L A S E R  

S Y S T E M S

The Professional Standard

To ensure a reliable use, do not use zinc-carbon batteries. 
Change batteries when battery symbol is flashing.

features

INSERT BATTERIES

The orientation of 
the endpiece is 
automatically detected 
and the zero point is 
accordingly adjusted.

MULTIFUNCTIONAL ENDPIECE

menu switch

KEY  

DESCRIPTION

Short Key press: Switch on / Laser on / Measure 

1x press = add +  / increase
1x press = subtract -  /decrease

....
1x key press = area
2x key press = volume

.....

1x press = stake out only with 1 value
2x press = Pythagoras 1
3x press = Pythagoras 2
4x press = Pythagoras 3

default = measure from back of device
1x press = measure from front
2x press = measure from tripod screw => (tripod symbol)

Measure from endpiece is automatically detected
Press for 2sec to change unit

1x press = memory of 10 displays
press this key for 2sec = take main value for further 
calculations

1x press = step back or clear last value
2x press = clear all

as usual - press for 2sec to turn off

DISTANCE UNIT 

SETTING

 

 

ELECTROMAGNETIC COMPATIBILITY (EMC)

safety instructions

This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules.

LASER CLASSIFICATION

 

 

! WARNING

Laser Class 2 products:

Do not stare into the laser beam or direct it towards other people 
unnecessarily. Eye protection is normally afforded by aversion 
responses including the blink reflex.

        

WARNING

Looking directly into the beam with optical aids (e.g. binoculars, 
telescopes) can be hazardous.

        

CAUTION

Looking into the laser beam may be hazardous to the eyes.

!

!

The device produces visible laser beams 
which are emitted from the instrument:
It is a Class 2 laser product in 
accordance with:

•  IEC60825-1 : 2007 Radiation safety of 

laser products“

LABELLING

 

 

Laser Radiation 

Do not stare into the beam 

Laser class 2 

acc. IEC 60825-1:2007 

Maximum radiant power: <1mW 

Emitted wavelength: 620-690nm 

Beam diver ence: 0.16 x 0.6 mrad 

Impulse duration: 0.2 x 10

-9

s - 0.8 x 10

-9

Subject to change (drawings, descriptions and technical 
data) without prior notice.

safety instructions

The person responsible for the instrument must ensure that all users 

understand these directions and adhere to them.

Areas  of responsibility

Responsibilities of the manufacturer of the original equipment:

PLS • Pacific Laser Systems

2500 Kerner Blvd.

San Rafael, CA 949401

The company above is responsible for supplying the product, 

including the User Manual in a completely safe condition.

The company above is not responsible for third party accessories.

Responsibilities of the person  in charge  of the 

instrument:

• To understand the safety instructions on the product and the 

instructions in the User Manual.

• To be familiar with local safety regulations relating to accident 

prevention.

• Always prevent access to the product by unauthorized 

personnel

Permitted use

•  Measuring distances

•  Tilt measurement

Prohibited use

•  Using the product without instruction

•  Using outside the stated limits

•  Deactivation of safety systems and removal of explanatory 

   and hazard labels

•  Opening of the equipment by using tools

   (screwdrivers, etc.)

•  Carrying out modification or conversion of the product

•  Use of accessories from other manufacturers without 

   express approval

•  Deliberate dazzling of third parties; also in the dark

•  Inadequate safeguards at the surveying site

   (e.g. when measuring on roads, construction sites, etc.)

•  Deliberate or irresponsible behavior on scaffolding, when using 

ladders, when measuring near machines which are running or 

near parts of machines or installations which are unprotected

•  Aiming directly in the sun

safety instructions

Hazards in use

WARNING

Watch out for erroneous measurements if the instrument is 

defective or if it has been dropped or has been misused or 

modified. Carry out periodic test measurements, particularly after 

the instrument has been subject to abnormal use, and before, 

during and after important measurements.

CAUTION

Never attempt to repair the product yourself. In case of damage, 

contact a local dealer.

WARNING

Changes or modifications not expressly approved could void the 

user’s authority to operate the equipment.

Limits of use

Refer to section "Technical data". The device is designed for use 

in areas permanently habitable by humans. Do not use the 

product in explosion hazardous areas or in aggressive 

environments.

 

Disposal

CAUTION

Flat batteries must not be disposed of with household waste. 

Care for the environment and take them to the collection points 

provided in accordance with national or local regulations.

The product must not be disposed with household waste.

Dispose of the product appropriately in accordance with the 

national regulations in force in your country.

Adhere to the national and country specific regulations.

Product specific treatment and waste management can be 

downloaded from our homepage.

 

message codes 

If the message Error does not disappear after switching on the 

device repeatedly, contact the dealer. If the message InFo 

appears with a number, press the Clear button and observe the 

following instructions:

  

Cause  

 

Correction

  

 

 

 

204 

Calculation error 

 

252 

Temperature too high 

253 

Temperature too low  

 

255 

Received signal too 

 

weak, measuring 

 

time too long

256 

Received signal 

 

too high

257 

Too much back- 

 

ground light

258 

Measurement outside 

 

of measuring range

260 

Laser beam 

 

interrupted

Perform measurement again.

Let device cool down.

Warm device up.

Change target surface

(e.g. white paper).

Change target surface

(e.g. white paper).

Shadow target area.

Correct range.

Repeat measurement.

•  Clean the device with a damp, soft cloth.

•  Never immerse the device in water.

•  Never use aggressive cleaning agents or solvents.

technical data

technical data

warranty

This product is warranted by PLS · Pacific Laser Systems to 

the original purchaser to be free from defects in material and 

workmanship under normal use for a period of two year from 

the date of purchase. During the warranty period, and upon 

proof of purchase, the product will be repaired or replaced 

(with the same or similar model at our option), without charge 

for either parts or labor, through PLS. The purchaser shall bear 

all shipping, packing and insurance costs. Upon completion of 

the repair or replacement, the unit will be returned to the 

customer, freight prepaid. The warranty will not apply to this 

product if it has been misused, abused or altered. Without 

limiting the foregoing, battery leakage, dents or gouges to the 

plastic housing, broken optic windows, damage to the 

switch/LED membrane are presumed to result from misuse or 

abuse. Tampering with or removal of the caution or 

certification labels voids this warranty.

Neither this warranty nor any other warranty, express or 

implied, including implied warranties of merchantability,

shall extend beyond the warranty period. No responsibility 

is assumed for any incidental or consequential damages. 

This warranty gives you specific legal rights, and you may 

have other rights which vary from state to state.

care 

Distance measurement

 

Typical Range*  

0.05-80 m / 2-265 ft

 

Range  at unfavourable  

60 m / 197 ft 

condition 

*

***

 

  

 

mm /

  1/  in

General

 

Laser class  

2

 

Laser type 

635 nm, < 1 mW

 

Protection class  

IP54 (dust- and 

splash water 

 

Autom. laser  switch  off  

after 90 

 

Autom. power  switch-off  

after 180 

Battery durability  (2 x AAA)     

up to 3000 measure- 

ments

 

Dimension  (H  x D  x  W)  

120 x 58 x 29 mm  

                                                         (4.7 x 2.3 x 1.2 in )

 

Weight (with  batteries)  

146 g / 4.98 oz

 

Temperature range:

 

-  Storage 

-25 to 70 °C 

-13 to 158 °F 

-  Operation 

-10 to 50 °C 

14 to 122 °F

 

 

Functions

 

Distance measuring 

yes

 

Min/Max measuring  

yes

 

Permanent measuring 

yes

 

Stake-out  

yes

 

Addition/Subtraction  

yes

 

Area  

yes

 

Volume  

yes

 

Pythagoras  

3-point, partial height

 

Memory  

10 displays

 

Beep  

yes

 

Illuminated display  

yes

 

Multifunctional  endpiece  

yes

 

 

* applies  for 100 % target reflectivity (white painted 

wall), low background illumination, 25 ºC

** Tolerances apply from 0.05 m to 10 m with a 

confidence level of 95%. The maximum tolerance may 

deteriorate to 0.1 mm/m between 10 m to 30 m and to 

0.20 mm/m for distances above 30 m

*** applies for 100 % target reflectivity, background 

illumination of approximately 30'000 lux

For accurate indirect results, the use of a tripod is 

recommended. For accurate tilt measurements a 

transverse tilt should be avoided.

Target surfaces: Measuring errors can occur when 

measuring to colorless liquids, glass, styrofoam or 

semi-permeable surfaces or when aiming at high gloss 

surfaces. Against dark surfaces the measuring time 

increases.

 

DISPLAY

ON / MEASURE

AREA / VOLUME

MEMORY

CLEAR / OFF

STAKE-OUT / 
PYTHAGORAS

SUBTRACT

MEASURE / UNITS

Measuring Accuracy                      +/-

16

seconds

seconds

1. 5 

ADD

**

2 sec

0.0000m
0.000m 
0.00m
 

Switch between the 

following units:

0.00 ft. 
0.00 1/32 
0.00 in. 
0 1/32

Reviews: