TROUBLESHOOTING GUIDE
ISSUE
POTENTIAL CAUSE
PROPOSED SOLUTION
MANUAL SECTION
INSUFFICIENT WATER TO
SCRUB HEAD
SOLUTION FLOW SETTING IS TOO LOW
ADJUST SOLUTION CONTROL
SOLUTION DISTRIBUTION
SOLUTION TANK IS EMPTY
ADD WATER/SOLUTION TO THE TANK
SOLUTION DISTRIBUTION
IN-LINE SOLUTION FILTER IS CLOGGED
REMOVE AND CLEAN THE FILTER
SOLUTION DISTRIBUTION
SOLUTION TUBE IS CLOGGED, KINKED, OR DAMAGED
INSPECT TUBES
PARTS DIAGRAMS
SOLUTION SHUT OFF VALVE IS CLOSED
OPEN VALVE
SOLUTION DISTRIBUTION
SOLUTION SOLENOID VALVE MAY BE FAULTY
VERIFY OPERATION AND REPLACE IF NECESSARY
PARTS DIAGRAMS
POOR WATER RECOVERY
RECOVERY TANK IS FULL
EMPTY RECOVERY TANK
RECOVERY SYSTEM
DIRTY OR WORN SQUEEGEE BLADES
INSPECT AND ROTATE OR REPLACE AS REQUIRED
RECOVERY SYSTEM
RECOVERY HOSE LOOSE OR DAMAGED
INSPECT AND REPAIR
PARTS DIAGRAMS
RECOVERY HOSE OR SQUEEGEE ASSEMBLY HAS AN
OBSTRUCTION
CLEAR OBSTRUCTIONS FROM RECOVERY SYSTEM
PARTS DIAGRAMS
SQUEEGEE ASSEMBLY MAY BE OUT OF ADJUSTMENT
ADJUST AS NECESSARY
RECOVERY SYSTEM
STUCK OR DAMAGED BALL FLOAT
INSPECT AND REPAIR/REPLACE
RECOVERY SYSTEM
RECOVERY TANK LID IS NOT SEALING PROPERLY
INSPECT RECOVERY LID GASKET. REPAIR OR REPLACE IF NEEDED
PARTS DIAGRAM
DRAIN HOSE CAP IS NOT INSTALLED PROPERLY
INSTALL DRAIN HOSE SECURELY
RECOVERY SYSTEM
LOW BATTERY VOLTAGE
CHARGE BATTERIES
CHARGING
MACHINE WILL NOT
TURN ON
FAULTY KEY SWITCH
DIAGNOSE AND REPLACE
WIRING DIAGRAMS
DISCHARGED BATTERIES
CHARGE BATTERIES
CHARGING
LOOSE OR DAMAGED WIRE
REPAIR
WIRING DIAGRAMS
MACHINE NOT
CLEANING FLOOR
PROPERLY
WORN PAD OR BRUSH
INSPECT AND REPLACE AS REQUIRED
SCRUB DECK SETUP
WRONG PAD OR BRUSH FOR APPLICATION
CONTACT YOUR LOCAL DISTRIBUTOR FOR RECOMMENDED APPLICATION
SCRUB DECK SETUP
INSUFFICIENT CLEANING SOLUTION FOR APPLICATION ADJUST THE MIXTURE AS REQUIRED
SOLUTION DISTRIBUTION
EXCESSIVE FOAM IN
RECOVERY TANK
IMPROPER DETERGENT TYPE
USE A LOW-FOAM DETERGENT OR ADD A DEFOAMING AGENT TO THE
RECOVERY TANK. READ ALL CHEMICAL LABELS THOROUGHLY BEFORE USE
RECOVERY SYSTEM
MIXTURE SETTING TOO HIGH ON OPTIONAL
CHEMICAL INJECTION SYSTEM
USE A LOW-FOAM DETERGENT OR ADD A DEFOAMING AGENT TO THE
RECOVERY TANK. READ ALL CHEMICAL LABELS THOROUGHLY BEFORE USE
RECOVERY SYSTEM
VACUUM MOTOR WILL
NOT RUN
SQUEEGEE LIFT LEVER IS STILL RAISED
LOWER SQUEEGEE LEVER
RECOVERY SYSTEM
VACUUM RELAY MAY BE FAULTY
CONTACT SERVICE TECHNICIAN TO TROUBLESHOOT AND ISOLATE
WIRING DIAGRAMS
VACUUM SWITCH OR WIRING MAY BE FAULTY
CONTACT SERVICE TECHNICIAN TO TROUBLESHOOT AND ISOLATE
WIRING DIAGRAMS
VACUUM MOTOR WILL
NOT TURN OFF
STILL IN DELAY MODE
ALLOW 10 SECONDS FOR VACUUM TO SHUT DOWN
RECOVERY SYSTEM
VACUUM RELAY MAY BE FAULTY
CONTACT SERVICE TECHNICIAN TO TROUBLESHOOT AND ISOLATE
WIRING DIAGRAM
(PAGE 1 OF 2)
Summary of Contents for S-24
Page 5: ...PAGE INTENTIONALLY BLANK ...
Page 48: ...RETURN TO TABLE OF CONTENTS 43 FRAME ASSEMBLY ...
Page 52: ...RETURN TO TABLE OF CONTENTS 47 SOLUTION TANK ...
Page 54: ...RETURN TO TABLE OF CONTENTS 49 OPTIONAL CHEMICAL INJECTION SYSTEM ...
Page 64: ...RETURN TO TABLE OF CONTENTS 59 S 24 DISK SCRUB HEAD ...
Page 66: ...RETURN TO TABLE OF CONTENTS 61 S 24 DISK SCRUB HEAD ...
Page 79: ...RETURN TO TABLE OF CONTENTS 74 PAGE INTENTIONALLY BLANK ...
Page 85: ...RETURN TO TABLE OF CONTENTS 80 OPTIONAL CHEMICAL INJECTION SYSTEM ...
Page 86: ...RETURN TO TABLE OF CONTENTS 81 OPTIONAL SCRUBSMART TELEMETRY SYSTEM ...
Page 87: ...RETURN TO TABLE OF CONTENTS 82 PAGE INTENTIONALLY BLANK ...
Page 88: ...RETURN TO TABLE OF CONTENTS 83 DATE MAINTENANCE LOG ...
Page 89: ...RETURN TO TABLE OF CONTENTS 84 DATE MAINTENANCE LOG ...
Page 91: ...RETURN TO TABLE OF CONTENTS 86 PAGE INTENTIONALLY BLANK ...
Page 92: ...www pacificfloorcare com ...