Pacific energy The Mirage A Series Installation And Operating Instructions Manual Download Page 3

3

CAUTION

FOR YOUR SAFETY -

 Do not install or operate your Pacific Energy

Mirage without first reading and understanding this manual.  Any
installation or operational deviation from the following instructions
voids the Pacific Energy Gas Stove Warranty and may prove
hazardous.

This appliance and its individual shutoff valve must be disconnected
from gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig. (3.5 kPa)

This appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig. (3.5 kPa)

SAFETY

Due to high temperatures, this gas appliance should be

located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high

surface temperature and should stay away to avoid burns or
clothing ignition.

Young children should be carefully supervised when they

are in the same room as the appliance.

Clothing or other flammable material should not be placed

on or near the appliance.

Any grill, panel or door removed for servicing the unit must

be replaced prior to operating.  Failure to do so may create  a
hazardous condition.

Installation and repair should be done by a qualified service

person.  The appliance should be inspected before use and at
least annually by a professional service person.  More frequent
cleaning may be required due to excessive lint from carpeting,
bedding material, etc.  It is imperative that control compart-
ments, burners and circulating air passageways of the appli-
ance be kept clean.

It is Pacific Energy’s policy that no responsibility is assumed by the
Company or by any of its employees or representatives for any
damages caused by an inoperable, inadequate, or unsafe condition
which is the result, either directly or indirectly, of any improper
operation or installation procedures.

MAINTENANCE

Caution:

  Turn off gas and electrical power supply and allow ample

time for unit to cool before servicing appliance.  It is recommended
that this appliance and venting should be inspected at least once a
year by a qualified service person.
Do not use this heater if any part has been under water. Immediately
call a qualified service technician to inspect the heater and to replace
any part of the control system and any gas control which has been
under water.

Annual Inspection:

a)  Clean louvres and air passage ways of excessive lint build-up
from carpeting, bedding material, etc. The flow of combustion and
ventilation air must not be obstructed.

b)  Remove glass panel and log set.  Inspect logs and burner
assembly for lint and soot build-up.  If excessive build-up of soot is
present, have a qualified serviceman inspect and adjust unit for
proper combustion.  Clean logs and burner with a vacuum cleaner,
paying close attention to port on burner.

c)  Check the pilot system for proper operation.  (See Fig. #1)

d) Check that the chimney flue and its outlet are open and free from
blockage or debris.

e)  Check glass panel gasket, replace if necessary.

Note: 

 The appliance area must be kept clear and free from

combustible materials, gasoline and other flammable vapours and
liquids.

Periodically:

a)  Viewing glass may be cleaned with glass cleaner.
b)  Exterior porcelain enamel finish may be cleaned with soap and
water.

Note:

  Never use abrasives to clean this appliance.

ELECTRODE

BURNER

THERMOPILE

PILOT FLAME

Fig. # 1

f i r e - p a r t s . c o m

Summary of Contents for The Mirage A Series

Page 1: ...asoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installati...

Page 2: ...TENANCE 3 LIGHTING INSTRUCTIONS 4 OPERATING 5 BURNER 5 CONTROL 5 GAS FLAME ADJUSTMENT 5 GAS SUPPLY 6 ELECTRICAL 6 BLOWER OPERATION 6 CLEARANCES 6 INSTALLATION AND VENTING 7 FLOOR PROTECTION 7 LOG SET 8 REPLACEMENT PARTS 9 fire parts com ...

Page 3: ...e appli ance be kept clean It is Pacific Energy s policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable inadequate or unsafe condition which is the result either directly or indirectly of any improper operationorinstallationprocedures MAINTENANCE Caution Turn off gas and electrical power supply and allow ample ...

Page 4: ...y electric switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician F...

Page 5: ...ufacturing process This condition is temporary Open doors and windows to ventilate area GAS FLAME ADJUSTMENT The air shutter on the burner venturi tube controls the primary combustion air to the gas burner Although it is preset at the factory some adjustment may be necessary to obtain desired flame and to eliminate carbon deposits See Fig 4 for proper flame pattern Naturalgas 3 16 open Propanegas ...

Page 6: ... remove burner assembly 1 Lift glass up by the bottom tabs until it clears the bottom shelf andremove 2 Remove all logs from firebox taking care not to damage them 3 Remove 2 screws located in the front bottom holding burner in place see Fig 6 4 Lift burner up on the left side just enough to slide whole assembly to the left to disconnect from the orifice 5 Remove burner through front opening To re...

Page 7: ...ng with the vent safety shutoff system can result in carbon monoxide CO poisoningandpossibledeath Note This appliance has a draft hood built in and when installed according to these instructions the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the appliance Adequate combustion and ventilation air must be provided for safe and proper operation The Mirage Gas Ap...

Page 8: ...cing rear and the bark side forward The tabs should fit into notches of log 2 Place the large middle log on centre tabs of burner assembly Locate log on top of tabs with flat part down hollow part facing rear and bark side facing forward 3 Front log locates on channel in front of burner Flat part down and curve up on the left side 4 The top Y log bridges across from the front log to the large cent...

Page 9: ... FITTING 38 INLET PIPE 39 BURNER SUPPLY TUBE 40 ORFICE CONNECTOR FITTING 41 ORIFICE NAT GAS 42 ORIFICE LP 43 VENTURI TUBE 44 VENTURI GASKET 45 BURNERASSEMBLY 46 PILOT ASSEMBLY NAT GAS 47 PILOT ASSEMBLY LP 48 PILOT ORIFICE NAT GAS 49 PILOT ORIFICE LP 50 THERMOPILE 51 PILOT SUPPLY TUBE 52 BUSHING 53 WIRE STRAIN RELIEF 54 WIRE NUT 55 CONTROL BRACKET 56 ORIFICE HOLDER 57 1 4 SPACER 58 CONTROL PANEL BR...

Page 10: ...10 Fig 14 fire parts com ...

Page 11: ...11 Fig 15 fire parts com ...

Page 12: ...12 Printed in Canada Pacific Energy Gas Stoves Box 29 1394 Fisher Road Cobble Hill B C V0R 1L0 fire parts com ...