Screws
Figure 8: Control assembly screws.
Power cord
in slot
Figure 9: Control assembly.
Screws
Strain relief
Figure 10: Cord strain relief.
Power Cord Position
The power cord for the NEO 1.6 Insert comes factory set to exit the right side of the unit. If you desire, the
cord can be switched to exit to the left of the unit. The cord will lose approximately 12” of length when exit-
ing the left side of the unit.
Follow these instructions to switch the cord direction.
1. Remove the two screws securing the control assembly to the unit and then disconnect the wires leading
to the right side blower (Figure 8).
2. Remove the power cord from the slot in the right side end of the control assembly (Figure 9).
3. Remove the two screws securing the backing plate with the strain relief in it and rotate 180 degrees.
4. Engage the power cord in the slot on the left side end of the control assembly.
5. Reconnect the wires to the right side blower and reinstall the control assembly on the unit.
NEO 1.6 INSERT-A_310816-32
16
5055.750