INSTALLATION 
A N D   O P E R AT I N G 
INSTRUCTIONS

220514 -20 

VISTA and CLASSIC-C                                                                              5055.3AS

Models
Pacifi c VISTA
VISTA CLASSIC
SERIES - C

SAFETY NOTICE

If this stove is not properly installed, a 
house fi re may result.  For your safety, 
follow the installation instructions.  Contact 
local building or fire officials about 
restrictions and installation inspection 
requirements in your area.

IMPORTANT:

THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER

SERIAL #

Summary of Contents for Pacific VISTA

Page 1: ...IES C SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety followtheinstallationinstructions Contact local building or fire officials about restrictions and in...

Page 2: ...ctions may result in property damage bodily injury or even death 2 220514 20 Contents Safety and Maintenance 3 Maintenance Checks 4 Creosote 5 Formation and Need for Removal 5 Chimney Fires 5 In Case...

Page 3: ...le liquid to start a fire Do not burn garbage or flammable fluids such as gasoline naphtha or engine oil We strongly recommend that smoke detectors be installed 2 Removeashesfrequently Emberscanrollou...

Page 4: ...e Chimney System Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacu...

Page 5: ...certain amount of creosote is inevitable and must be lived with Regular inspection and clean ing is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildu...

Page 6: ...t on its back and removable cover of the ash drawer enclosure facing up align mounting holes with studs on stove bottom 2 Position the legs on the stove 3 Place the 1 2 washers over the studs and secu...

Page 7: ...TED TO AS NZS 4013 ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHOR ITY IS CONSIDEREDTO BE IN BREACH OFTHEAPPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013...

Page 8: ...or Protector Floor Protector Thestovemaybeinstalledonacombustiblefloorprovidedember protectionmadefroma6mmthicknon combustiblematerialwith a thermal conductivity value of 4w m degree K This protection...

Page 9: ...mney flue serving another appliance Minimum system height is 4600mm measured from base of appliance Installation Procedure 1 Install all components to the chimney manufacturer s installation requireme...

Page 10: ...size brick With the heater in the upright position install firebricks as follows First install 4 full size firebricks against the rear wall Next install the side firebricks 2 full size each side Lastl...

Page 11: ...to be secured to the structure to prevent dislodging of the air duct To draw outside air from behind the stove an outside air adaptor may be required cut or drill a 100mm hole through a wall behind t...

Page 12: ...f carbon monoxide a taste less odourless gas that can kill Under no circumstances should you attempt to barbecue in this heater How to Test Your Wood Add a large piece of wood to the stove when it has...

Page 13: ...roximately 25mm deep on the firebox bottom to help maintain a hot charcoal bed Optional ash cleanout system The ash dump handle is located under the ash lip on the left hand side To oper ate ash dump...

Page 14: ...air for combustion 4 Door gasket leakage Replace gasket Check latch EXCESSIVE CREOSOTE BUILDUP See 1 2 3 above LOW HEAT OUTPUT 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft...

Page 15: ...Door casting Brushed NIkel CAST 16BNI 10 Door handle assembly WODC 4147C 11 Firebrick set BRIC VISTA 12 Brick rail set VIST RAILSET 13 Rail extensions 2 pc VIST RAILEXT 14 Baffle kit VIST BAFKIT 15 F...

Page 16: ...4147C 11 Firebrick set BRIC VISTA 12 Brick rail set VIST RAILSET 13 Rail extensions 2 pc VIST RAILEXT 14 Baffle kit VIST BAFKIT 15 Flame shield c w nut bolt VIST 2115 16 Air shutter assembly VIST 453...

Page 17: ...ding the basic functions of this design Traditionalwoodstoveshadabasiccombustion systemwhichallowedaconsiderableamountof heat energy to escape up the chimney as un burned gases and particulates smoke...

Page 18: ...18 220514 20...

Page 19: ...L AVERAGE EFFICIENCY BURNING HARDWOOD 67 WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 Distributed by PIVOT STOVE HEATING CO 234 238 MOORABOOL STREET GEELONG VIC 3220 pivotstoves com au PACIFIC ENERGY FI...

Page 20: ...20 220514 20 Printed in Canada PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 6V8 Phone 250 748 1184 Web site www pacificenergy net...