30
INSTALLER
INFORMATION
Caution:
Label all wires prior to
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Wiring Diagram
Page 1: ...diately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed...
Page 2: ...ireplace 16 Venting 17 Plumbing and Electrical 19 Gas Supply 20 Gas Pressure Check 20 Gas Pressure Testing Procedure 21 Pilot Adjustment 21 Propane Conversion 22 Door Installation Removal 23 Fan Insta...
Page 3: ...psi 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressu...
Page 4: ...ot viewing glass is provided with the appliance and shall be installed If the barrier becomes damaged the barrier shall be replaced with the manufacturers barrier for this appliance Any grill panel or...
Page 5: ...manual and pay close attention to all Safety Warnings The manual contains important information on the unit s safe operation and maintenance When lit for the first time the fireplace will emit a sligh...
Page 6: ...gas valve and stepper motor Transmitter Remote Control with LCD Display The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display Figure 1 The transmit...
Page 7: ...itter is used then press the button SW1 to exit the synchronization phase The system is now initialized IFC Module The Proflame 2 Integrated Fireplace Control IFC board is a device that allows the aut...
Page 8: ...of the command Turn off the Appliance With the system ON press the ON OFF key on the transmitter The transmitter LCD display will only show the room temperature At the same time the IFC will be comman...
Page 9: ...display on the transmitter will change to show that the room thermostat is ON and the set temperature is now displayed Figure 7 To adjust the set point press the up or down arrow keys until the desire...
Page 10: ...0 Use the Up Down Arrow Keys Figure 1 to turn on off or adjust the fan speed Figure 10 A single beep will confirm reception of the command Continuous Pilot Intermittent Pilot CPI IPI selection With th...
Page 11: ...point etc When the IFC batteries are low a double beep will be emitted from the IFC board when it receives a command from the transmitter This is an alert for a low battery condition for the IFC boar...
Page 12: ...r assemblies for soot buildup If excessive buildup of soot is present have a qualified service person inspect and adjust unit for proper combustion Clean burners with a brush or vacuum cleaner paying...
Page 13: ...13 OWNER S INFORMATION Section 2 Lighting Instructions...
Page 14: ...ve grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size...
Page 15: ...R SIDE WALL 4 INTERIOR BACK WALL 4 INTERIOR CEILING 4 IN FRONT OF APPLIANCE 36 EXTERIOR SIDE WALL 8 VENTING CLEARANCE 1 EXTERIOR SOFFIT 30 NCR STANDS FOR NO CLEARANCE REQUIRED YOU MAY USE COMBUSTIBLE...
Page 16: ...is to be installed location of vent system and where gas supply piping may be plumbed Various installations are possible such as next to an existing wall a corner an alcove or a wall projection Due to...
Page 17: ...st be constrained to the boundaries of this chart A Maximum of three 3 90 elbows may be used Only one 1 90 elbow or combination of other elbows equalling 90 can be used without reducing horizontal run...
Page 18: ...gure 17 Venting This fireplace is certified for use with 4 x 6 5 8 coaxial venting components only It is permitted to only use certified venting for this appliance See charts on page 29 for a list of...
Page 19: ...ections start by positioning the gas fireplace Connect the gas supply line to the 1 2 flare fitting at the rear of the unit as seen in Figure 16 Please see the gas supply section of the manual for req...
Page 20: ...ply line going to the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve It is essential that a union or flanged connec...
Page 21: ...ints on the valve which can be seen in Figure 18 After locating test ports loosen the screws within the ports using a flat tip screwdriver 3 Attach pressure gauge to the test ports 4 Turn gas supply b...
Page 22: ...to ensure a proper seal when installed To replace the pilot orifice you will need to remove the pilot hood which is held in place by a spring First remove the spring and then remove the hood by pulli...
Page 23: ...al Installation 1 Connect wiring to the fan and insert into the fireplace through the side of the unit 2 Insert both screws into the fan access panel to attach the fan to the unit as in Figure 24 3 Re...
Page 24: ...the second side panel Removal 1 Remove first side panel by pulling the top edge of panel into the firebox chamber until there is enough room to move the panel away from the wall When you have enough...
Page 25: ...Burner Tray Glass Kit Installation To install the glass evenly spread a thin layer of crushed glass across the entire burner pan as seen in Figure 30 Figure 30 Glass Installation Log Set Installation...
Page 26: ...n in Figure 37 6 Slide front side of left side cladding into front clamps as shown in Figure 38 Secure back with hex bolts as shown in Figure 39 7 Repeat step 6 for the right side cladding Removal 1 U...
Page 27: ...27 INSTALLER INFORMATION Figure 36 Front Cladding Securement Figure 37 Side Cladding Stand Figure 38 Side Cladding Figure 39 Side Cladding Securement...
Page 28: ...5002 50 10 Replacement Aluker Panel Set GMIR 5099 G958 Aesthetic Components Description Order Number Exterior Ceramic Panels by Piazzetta Mirage Surround Classic Bordeaux PZSY P958CBX Mirage Surround...
Page 29: ...MATION NOTE Mixing venting components from different manufacturers is inadvisable Figure 40 4 x6 5 8 Rigid Piping Cross Reference Chart Figure 41 4 x6 5 8 Rigid Pipe Components Cross Reference Chart V...
Page 30: ...NSTALLER INFORMATION Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Wiring Diag...
Page 31: ...______ __________________________________________________________________________________________________ ______________________________________________________________________________________________...
Page 32: ......