TESTED and LISTED to 

CAN/ULC S627 AND UL 1482

Meets the Environmental Protection Agency’s

May 2015 Particulate Emission Standards

PLEASE SAVE THESE  INSTRUCTIONS

By Pacific Energy

INSTALLATION & OPERATION GUIDE

ALDERLEA T6 CAST IRON WOOD STOVE

MODEL: ALDERLEA T6

(STANDARD OR CLEARVIEW DOOR)

 

SERIES: B

SAFETY NOTICE

If this stove is not properly installed, a house fire may result.  For your safety, 
follow the installation instructions.  Contact local building or fire officials about 
restrictions and installation inspection requirements in your area.

190617-24       

AL6B

5055.3272

SERIAL #

©PACIFIC ENERGY FIREPLACE 

PRODUCTS LTD. - 2017

Summary of Contents for ALDERLEA T6

Page 1: ...E ALDERLEA T6 CAST IRON WOOD STOVE MODEL ALDERLEA T6 STANDARD OR CLEARVIEW DOOR SERIES B SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area 190617 24 AL6B 5055 3272 SERIAL PACIFIC ENERGY FIREPLACE PRODUCTS ...

Page 2: ... Label 23 PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of theAlderlea T6 Freestanding wood heater This heater meets the 2015 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2015 Under specific test conditions this heater has been shown to deliver heat at rates ranging from 11 100 to 34 600 Btu hr NOTE WE STRO...

Page 3: ...glass only Do not substitute with any other type GLASS SIZE 20 125 511mm x 11 875 302mm x 5mm To remove broken glass undo the four retaining screws and remove clamps noting position for re assembly Remove all particles of glass Be careful as they are very sharp Install new glass complete with gasket Replace clamps and screws 6 Do not store wood within heater installation clearances or within the s...

Page 4: ...at shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacumn on the grill openings in the back and bottom of the blower casing to remove any dust and debris Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping greater than this or has cracking or breakage Please cont...

Page 5: ...sed Wet or green wood contributes significantly to creo sote formation as the excess moisture that is boiled off cools the fire making it difficult for the tars and gases to ignite thus creating dense smoke and poor combustion This moisture laden smoke cools the chimney compounding the problem by offering the smoke the ideal place to condense In summary a certain amount of creosote is inevitable a...

Page 6: ...gns of a chimney fire may be one or more of the following 1 A roaring sound 2 Vibration of the chimney 3 Flames and sparks shooting out of the top of the chimney In Case of a Chimney Fire 1 Immediately close the air inlets on the stove 2 Evacuate the home and call the local fire department 3 After the chimney fire has been extinguished the chimney must be cleaned and checked for stress and crackin...

Page 7: ...onnectorareshown in Figure 2 Clearancesmaybereducedwithvariousheatinsulatingmaterials Consultlocal National fire codes and authorities for approval 3 Alternately for close clearances use a listed double wall connector See Figure 2a Installation Residential Warning Under no circumstances is this heater to be installed in a makeshift or temporary manner It may be fired only after the stove is instal...

Page 8: ...red at every joint and collar with 3 sheet metal screws Installed with the crimped or male ends pointing down This will carry any liquid creosote or condensation back into the stove The chimney connector shall not pass through an attic roof space closet or similar concealedspace floor orceiling Wherepassagethroughawall orpartitionofcombustible material is desired the installation shall conform to ...

Page 9: ...NFI as NFI woodburning Specialists or who are certified in Canada by Wood Energy Technical Training WETT BOTHCHIMNEYSYSTEMANDCONNECTORMUSTBELISTEDTO INCANADA ULC S 641 LISTED CONNECTORAND ULC S 629 LISTED CHIMNEY IN USA UL 103 HT LISTED CONNECTOR AND CHIMNEY Clearances Mobile Home This heater must be installed with listed double wall connector and compatible chimney system listed on page 10 Cleara...

Page 10: ...m CEILING HEIGHT NON COMBUSTIBLE FLOOR PROTECTOR 48 1219 mm 3 914 mm MINIMUM HOODED VENT OR 90º ELBOW TURNED DOWN The chimney may incorporate an offset To do this safely all sections of listed connector offset elbows and chimney section must be screwed together by at least three sheet metal screws per joint The chimney must be suitably supported by the chimney manufacturer s listed offset support ...

Page 11: ...afters before proceeding further 4 Cut a hole in the ceiling and roof to suit the chimney system and frame in the sides The chimney support is mounted to the framing 5 Assemblechimneysectionssothefinishedlengthisrestingonthesupportandprotruding through the roof Avoid having joints between ceiling and roof Install radiation shield Assemble flashing and storm collar and be sure to maintain the vapou...

Page 12: ...le of the ash box enclosure see page 6 Fig 1a Connect enclosure to the floor with a short 4 100mm diameter pipe This hole must get its air from a ventilated crawl space or be extended with duct to the outdoors see Figure 4 Page 10 The use of outside combustion air for residential installation requires the unit to be secured to the structure to prevent dislodging of the air duct Not e When installe...

Page 13: ...rcoal Garbage Solvents Lawn clippings yard waste Unseasoned wood Railroad ties Manure or animal remains Materials containing rubber including tires Materials containing plastic Waste petroleum products paints or paint thinners or asphalt products Materials containing asbestos Construction or demolition debris Paper products cardboard plywood or particleboard These materials contain chlorides which...

Page 14: ...s in this manual 1 Set air control to a desired setting If smoke pours down across the glass waterfall effect this indicates you have shut the control down too soon or you are using too low a setting As every home s heating needs vary based on insulation windows climate etc the proper setting can only be found by trial and error and should be noted for future burns 2 To refuel adjust air control t...

Page 15: ...ging of the chimney Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft Ash Removal Whenever ashes get 3 76mm to 4 102mm inches deep in your firebox and when fire has burned down and cooled remove excess ashes Leave an ash bed approximately 1 25 mm deep on the firebox bottom to help maintain a hot charcoal bed Ash Chute Operation Your Alderlea stov...

Page 16: ...d and may be installed at any time Follow installation instructions supplied with the kit Route power supply cord away from heater Electrical rating 115 volts A C 0 84 amps Fan output rating 140 CFM Blower Operation Proper blower speed matched with air control setting will ensure peak performance from your stove Operate as follows Air control set to low right position operate blower speed control ...

Page 17: ...reosote Buildup See 1 2 3 above See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set too high Set air control lower 2 Not enough wood Unsplit wood is preferred for overnight burns 3 Draft too high Excessive chimney height and or diameter 4 Poor qualit...

Page 18: ... 4805MBK 7 TOP GRILL ASSEMBLY 3 ALT6 TGASSYMBK 8 ASH DUMP ASSEMBLY WODC 2261 9 LEG CASTING ASSY 4 ALDR 4807MBK 10 BOOST MANIFOLD 3105 111 11 DOOR CATCH 4835 12 DOOR CROWN BLACK PAINT ALT6 4802MBK 13 ASHLIP BLACK PAINT ALT6 4801MBK 14 LEG ADAPTER AL6B LGADA 15 ASH PAN ASSY 4825 16 FAN OPTIONAL WODC BLOW 17 DOOR STOP LHS ALT6 4830MBK 18 AIR SHUTTER ASSEMBLY FSND 4631 19 AIR DEFLECTOR 4815 5 20 SECON...

Page 19: ...and 5 cut bricks A B C 2E with ash cleanout system 2 Next install the side firebricks 3 full size and 2 cut firebricks F on each side of the firebox as shown 3 Finally install 4 full size bricks against the rear wall as shown ITEM SIZE A 1 1 2 X 4 1 2 X 1 1 4 39 mm x 115 mm x 32 mm B 4 X 4 1 2 X 1 1 4 102 mm x 115 mm x 32 mm C 7 1 4 X 4 1 2 X 1 1 4 184 mm x 115 mm x 32 mm D 9 X 4 1 2 X 1 1 4 230 m...

Page 20: ...tly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required to be returned to Pacific Energy or an accredited agent transportation prepaid Porcelain is warranted for gloss retention Certain colors may darken when heated and return to the original shade when cool Glass is warranted ag...

Page 21: ...190617 24 AL6B PACIFIC ENERGY FIREPLACE PRODUCTS LTD 21 ...

Page 22: ...190617 24 AL6B PACIFIC ENERGY FIREPLACE PRODUCTS LTD 22 ...

Page 23: ...CONNECTOR INSTALLATION EN MAISON MOBILE UTILISANT UN RACCORD DE MUR DOUBLE WN 16391 ETL 4001507 INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D INSTALLATION ET D OPÉRATION FOURNI AVEC L APPAREIL CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX RESTRICTIONS PERMIS D INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION NE RELIEZ PAS CET APPAREIL À UN CONDUI...

Page 24: ... PACIFIC ENERGY FIREPLACE PRODUCTS LTD 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 For technical support please contact your retailer Web site http www pacificenergy net PRINTED IN CANADA ...

Reviews: