QR5/QR5IP SERIES MANUAL
file:///C|/PACH-CO.COM-2022-B/online_manual/qr5_manual.htm[4/25/2022 2:58:06 PM]
Function Code 44 Disable Time Zone Relay
The system's relay can be disabled during certain time but the system is still in full operation. Maximum 10 disable time
zones.
1.
2. Enter 44 then #
3. Enter 0-9 then pres #
4.
Enter
0= Delete the existing time zone then press #
or
1= add new time zone then press #
5.
Enter start time in military then press #
6.
Enter end time in military then press #
7.
Enter
0
= Sunday,
1
= Monday,
2
= Tuesday,
3
= Wednesday,
4
= Thursday,
5
= Friday,
6
= Saturday
then press #
Return to step 3 to program more time zone
Function Code 45 Relay 1 and 2 Unlock Timer