background image

QR5/QR5IP SERIES MANUAL

file:///C|/PACH-CO.COM-2022-B/online_manual/qr5_manual.htm[4/25/2022 2:58:06 PM]

QUANTUM QR5/QR5IP SERIES

PROGRAMMING MANUAL  V04122022

TABLE OF CONTENTS

Table of Contents Limitation of Liability

Products Limited Warranty

 

Limited Warranty Limits and Exclusions

CHAPTER 1 GETTING STARTED 

CHAPTER 2 INSTALLATION AND WIRING DIAGRAM 

General Wiring Diagram

CHAPTER 3 KEYPAD CORRELATION TABLE

CHAPTER 4 PROGRAMMING

Log-in to Programming Mode
Function Code 00: Change Master Code
Function Code 01: Add New Tenant Directory
Function Code 02: Edit Existing Directory
Function Code 03: Delete Tenant Directory
Function Code 04: Clear All Tenant Directories
Function Code 05: Enable or disable Call 
Function Code 06: Add New Access Code
Function Code 07: Delete Access Code
Function Code 08: Clear All Access Codes
Function Code 09: Access Code Digit

Function Code 23: Lock-out Count
Function Code 24: Alarm
Function Code 25: Keypad Beep
Function Code26: Door Beep
Function Code 27: Talk Time
Function Code 28: Unlock Relay 1 Time
Function Code 29: Unlock Relay 2 Time
Function Code 30: Enable Automatic Call Forwarding
Function Code 31: Call Forwarding Time
Function Code 32: Call Forwarding Directory
Function Code 33: Temporary Code
Function Code 34: Special Code
Function Code 35: Temporary Card
Function Code 36: Special Card
Function Code 38: System Acknowledge
Function Code 39: Disable and Enable Remote Access
Function Code 40: DTMF Relay 1
Function Code 41: DTMF Relay 2
Function Code 42: Relay 2 Mode
Function Code 43: Do Not Disturb Zone
Function Code 44: Disable Time Zone Relay
Function Code 45: Relay 1 and 2 Unlock Timer
Function Code 46: Firmware Version
Function Code 48: PBX Enable
Function Code 49: Edit Existing Access Code,
Temporary Code and Special Code

Summary of Contents for Quantum QR5 Series

Page 1: ...Function Code 08 Clear All Access Codes Function Code 09 Access Code Digit Function Code 23 Lock out Count Function Code 24 Alarm Function Code 25 Keypad Beep Function Code26 Door Beep Function Code 27 Talk Time Function Code 28 Unlock Relay 1 Time Function Code 29 Unlock Relay 2 Time Function Code 30 Enable Automatic Call Forwarding Function Code 31 Call Forwarding Time Function Code 32 Call Forw...

Page 2: ...ny damages which may arise in installation or use of the Quantum QR5 or QR5IP Series Pach and Company does not assume liability for any incompatibility between the Quantum QR5 or QR5IP Series and users devices Pach Company reserves the right to make changes without prior notice to any products in order to improve reliability function or design PRODUCTS LIMITED WARRANTY If your product does not wor...

Page 3: ...ples this excludes damages for lost time lost calls or messages cost of having a unit removed or re install if applicable travel to and from the servicer ALL EXPRESS AND IMPLIED WARRATIES INCLUDING THE WARRANTY OF MERCHANTABILITY ARE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an...

Page 4: ... back and bottom panel Features Web Based programming on QR5IP Series Event recording Automatic Enrollment 10 tenants 100 cards 100 access codes 20 programmable time zones 10 programmable auto unlock schedules and 20 holiday schedules 10 programmable temporary cards and access codes for limited use 10 programmable unlock hold cards and access codes Accessories and Replacement parts Visit our web s...

Page 5: ...t device such exit switch postal lock etc 8 DOORS1 DOORS2 GND Door Sensor connect to door swicth to monitor door opening and closing 9 RS 485 Slave units connection up to 8 slave units 10 26 BIT Wiegand Input 11 12VDC and GND Factory use only to power the QWCM 12 QWCM Power and Communication connector Do Not remove the connector with the power On 13 QWCM ETHERNET PORT Connect to the Router or Swit...

Page 6: ... d e f 3 T U V t u v 8 G H I g h i 4 W X Y Z w x y z 9 J K L j k l 5 SPACE Cancel call Erase incorrect letter or number exit programming CALL ENTER EXCEPT PROGRAM CHAPTER 4 Programming Log in to Programming Mode 1 Press 0 and simultaneously then release the welcome screen will stop scrolling 2 Enter 4 digit master code default 0000 then press if you do not know the master code see chapter 2 step 8...

Page 7: ...directory number 2 3 or 4 digits depending on the setup see function code 19 then see Chapter 3 for keypad layout 4 Enter name up to 16 characters name can be a person name apartment number etc directory is sorted in alphabetical order then press 5 Enter the tenant phone number up to 16 digit land line VOIP or cellular number i e 9494982951 then press Return to step 3 to enter another tenant direc...

Page 8: ... digit then press or press to keep the existing phone number Return to step 3 to edit another tenant directory Function Code 03 Delete Tenant Directory 1 Log in to programming 2 Enter 03 then 3 Enter the tenant directory to be deleted then press if directory exists if directory does not exist Function Code 04 Clear All Tenant Directories 1 Log in to programming 2 Enter 04 then 3 Do the following P...

Page 9: ... Enter 0 disable default pr 1 enable then press Function Code 06 Add New Access Code An access code is a keyless entry code to open the door An access code can be programmed in 4 5 6 7 or 8 digits see function code 09 to change the access code digit 1 Log in to programming 2 Enter 06 then 3 Enter the access code 4 8 digit see function code 09 then press see Chapter 3 for keypad layout 4 Enter name...

Page 10: ...tem then press 9 Enter 0 no more additional time zone then press and return to step 3 to program another access code 1 add additional time zone then press and return to step 6 exit programming Function Code 07 Delete Access Code 1 Log in to programming 2 Enter 07 then 3 Enter code to be deleted then press if access code exists if access code does not exist Repeat this step to delete another code F...

Page 11: ...programming 2 Enter 09 then 3 Enter 4 5 6 7 or 8 default setting is 4 digit then press Function Code 10 Add Card 1 Log in to programming 2 Enter 10 then 3 Present the card or keyfob against the black window the card or keyfob number will show on the display or enter the last 8 digits of the number of the keyfob or card then press see Chapter 3 for keypad layout 4 Enter name up to 16 characters the...

Page 12: ...m then press 9 Enter 0 no more additional time zone then press and return to step 3 to add program another card 1 add additional time zone then press and return to step 6 exit programming Function Code 11 Delete Cards 1 Log in to programming 2 Enter 11 then 3 Present the card or keyfob against the black window the number will show on the display or enter the last 8 digits of the card or keyfob the...

Page 13: ...ng 2 Enter 12 then 3 Enter 1 to clear all keyfobs or cards press or to cancel Function Code 13 Set Time 1 Log in to programming 2 Enter 13 then 3 Enter HH in military time MM minute the press Function Code 14 Set Date 1 Log in to programming 2 Enter 14 then 3 Enter YYYY MM DD YYYY year MM Month DD Date then press 4 Enter ...

Page 14: ... RAM buffer can hold 800 2000 events The Events are stored as first in first out FIFO This function code will clear the event buffer 1 Log in to programming 2 Enter 15 then Enter 1 then to clear event buffer or to cancel deletion Function Code 16 Auto Unlock Schedule AUS Unlocking and locking the door as program automatically If the open time is 06 00 and close time 18 00 door 1 2 or both will unl...

Page 15: ...Saturday then press 8 Enter 1 Relay 1 door 1 2 Relay 2 door 2 3 Both relay 1 and 2 then press 9 Return to step 3 to enter another AUS Function Code 17 Time Zone TMZ A maximum of 20 Time Zones can be programmed and up to three time zones can be assigned to each access code or card to allow access during a certain time of the day 1 Log in to programming 2 Enter 17 then 3 Enter 01 20 00 24 hours acce...

Page 16: ...nday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press Return to step 3 to program more time zone Function Code 18 Holiday Zone HLD HLD is to ever ride Time Zone TMZ and Auto Unlock Schedule AUS during the holidays Up to 20 Holidays can be programmed 1 Log in to programming 2 Enter 18 then 3 Enter 01 20 then press 4 Enter 0 Delete the existing holiday zone then press or 1 ad...

Page 17: ...irectory can also be used for direct call 1 Log in to programming 2 Enter 19 then 3 Enter 2 3 or 4 digit then press Function Code 20 AUXIN1 AUXIN1 is used for input device such as postal lock infrared sensor exit button etc AUXIN1 is associated with relay 1 1 Log in to programming 2 Enter 20 then 3 Enter 0 disable default setting 1 Enable control by relay 1 open door interval see function code 28 ...

Page 18: ...s enabled then the calling feature is disabled 1 Log in to programming 2 Enter 21 then 3 Entert 0 disable 1 enable then press Function Code 23 Lock out Count The system will be disabled in about 60 seconds after pressing invalid access code or swiping invalid card as specified on the Lock out Count 1 Log in to programming 2 Enter 23 then 3 Enter 1 9 default 3 then press Function Code 24 Alarm The ...

Page 19: ... directory 0 9 then press Function Code 25 Keypad Beep Turn the keypad press beep On or Off 1 Log in to programming 2 Enter 25 then 3 Enter 0 off 1 On default then press Function Code 26 Door Beep Turn the door beep On or Off 1 Log in to programming 2 Enter 26 then 3 Enter 0 off 1 On default then press Function Code 27 Talk Time The amount of time the visitor can talk to the tenant The timer start...

Page 20: ...ime for relay 1 to trigger 1 Log in to programming 2 Enter 28 then 3 Enter 01 99 second then press Function Code 29 Unlock Relay 2 Time The amount of time for relay 2 to trigger 1 Log in to programming 2 Enter 29 then 3 Enter 01 99 second then press Function Code 30 Enable Automatic Call Forwarding 1 Log in to programming 2 Enter 30 then 3 Enter 0 disable default pr 1 enable then press ...

Page 21: ...ine call forwarding is provided by your local telephone service 1 Log in to programming 2 Enter 31 then 3 Enter 15 60 second then press 30 second default Function Code 32 Forwarding Directory 10 Call forwarding directory can be programmed on the system but only one can be enabled 1 Log in to programming 2 Enter 32 then 3 Enter 0 9 then press Function Code 33 Temporary Code The code will be expired...

Page 22: ...elay then press 8 Enter time zone set 1 3 then press 9 Enter 00 24 hours 20 see function code 17 then press 10 Enter Sat id 0 7 then press enter 0 if no satellite connected to the QR5 11 Enter 0 no more additional time zone then press and return to step 3 to program another temporary code 1 add additional time zone then press and return to step 8 exit programming Function Code 34 Special Code The ...

Page 23: ...igit code see digit setting on function code 09 see Chapter 3 for keypad layout 6 Enter name then press 7 Enter 1 relay 1 door 1 2 relay 2 door 2 or 3 both relay then press 8 Enter time zone 1 3 then press 9 Enter 00 24 hours 20 see function code 17 then press 10 Enter Sat ID 0 7 then press enter 0 if no satellite connected to the QR5 11 Enter 0 no more additional time zone then press and return t...

Page 24: ...he programming Up to 10 temporary cards can be programmed 1 Log in to programming 2 Enter 35 then 3 Enter 0 delete 1 add then press 4 Enter card 01 10 then press 5 Present the card or fob in front of the black window the system will register the card or fob 8 digit number printed then press see Chapter 3 for keypad layout 6 Enter name and press 7 Enter 1 relay 1 door 1 2 relay 2 door 2 or 3 both r...

Page 25: ...eturn to step 8 exit programming Function code 36 Special Card The card can be use to unlock hold open hold and use same code again to lock close door or gate Up to 10 special cards can be programmed 1 Log in to programming 2 Enter 36 then 3 Enter 0 delete 1 add then press 4 Enter code 01 10 then press 5 Enter 4 8 digit code see digit setting on function code 09 see Chapter 3 for keypad layout 6 P...

Page 26: ...rogram another temporary code 1 add additional time zone then press and return to step 8 exit programming Function Code 38 System Acknowledge The system will answer incoming outside call after the number of rings set If the line associated with the system is connected to fax machine alarm panel or any answering device Disable this function 1 Log in to programming 2 Enter 38 then 3 Press 0 disable ...

Page 27: ...is not used 1 Log in to programming 2 Enter 40 then 3 Press 1 9 9 is default setting then press Function Code 41 DTMF Relay 2 By default the DTMF remote opening relay 2 door 2 key number is set to 8 means pressing 8 will remotely trigger relay 2 door 2 The number can be changed by selecting 1 9 to trigger relay 2 door 2 Note by default remote access for relay 1 is set to 9 see function code 42 If ...

Page 28: ...ours of the days you can create Do Not Disturb Time Zone For example 22 00 06 00 Monday Sunday Up to 10 Do Not Disturb Time Zones ca be programmed 1 Log in to programming 2 Enter 43 then 3 Enter 0 9 then press 4 Enter 0 delete 1 add then press 5 Enter start time military time the press 6 Enter end time then press military time end time must be later than start time if start time 22 00 hour and end...

Page 29: ...n Maximum 10 disable time zones 1 Log in to programming 2 Enter 44 then 3 Enter 0 9 then pres 4 Enter 0 Delete the existing time zone then press or 1 add new time zone then press 5 Enter start time in military then press 6 Enter end time in military then press 7 Enter 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press Return to step 3 to program more time zone Functi...

Page 30: ...s or relay 2 door 2 then press then press Function Code 46 Firmware Version To check the system s firmware version 1 Log in to programming 2 Enter 46 then Function Code 48 PBX Enable If the system is installed behind a Private Branch Exchange PBX then 9 is necessary before dialing an outside line If this function is enabled then the system can only be dialing an outside line it cannot dial the ext...

Page 31: ...ess Function Code 49 Edit Existing Access Code Temporary Code and Special Code 1 Log in to programming 2 Enter 49 then 3 Editing an Access Code click here or Editing a Temporary Code click here or Editing a Special code then click here Function Code 50 Erase Memory to Factory Default Warning This function code will erase the memory to factory default no way to restore them unless the database has ...

Page 32: ...name then press to call the selected name 5 2 Opening Door Remotely Relay 1 door 1 press 9 Relay 2 door 2 press 8 5 3 Opening Door Using Access Code Temporary Code and Special Code Access code Standard Operation is keyless entry code to open the door and door will be closed automatically see function code 06 Temporary Code is used for limited number of times maximum 10 times then the code will be ...

Page 33: ... below The card reader antenna is mounted behind the black square window 5 5 Extending Talk Time The talk time timer is set on function code 27 The warning beep will be heard one minute before the talk time is expired It can be extended more another full cycle by pressing 5 6 Call the System from Remote Location 1 The system must be install in Intercom and Call Forwarding Mode Wiring Diagram or Ca...

Page 34: ... qr5_manual htm 4 25 2022 2 58 06 PM The QWCM Web Based module is included on QR5 or QR5IP Series Click here for QWCM manual QWCM DEFAULT SETTING IP 192 168 1 230 SUBNET 255 255 255 0 GATEWAY 192 168 1 1 DNS 192 168 1 1 USERNAME Administrator PASSWORD pach or 8888 ...

Reviews: