If no remote opening allow, disable it using this function code. Default setting is enabled.

1. 

Log-in to programming

2.  Enter 39 then #

3.  Press 

0

= disable remote access

1

= enable remote access (default)

then press #

Function Code 40 DTMF Relay 1

By default the DTMF remote opening relay 1 (door 1) key number is set to 9 means pressing 9 will remotely trigger relay 1
(door 1). The number can be changed by selecting 1-9 to trigger relay 1 (door 1). Note: by default remote access for relay
2 is set to 8, see 

function code 41

. If you set relay 1 for key number 8 then you MUST change relay 2 to different key

number even though relay 2 is not used.

1. 

Log-in to programming

2.  Enter 40 then #

3.  Press 1-9 (9 is default setting) then press #

Function Code 41 DTMF Relay 2

By default the DTMF remote opening relay 2 (door 2) key number is set to 8 means pressing 8 will remotely trigger relay 2
(door 2). The number can be changed by selecting 1-9 to trigger relay 2 (door 2). Note: by default remote access for relay
1 is set to 9, see 

function code 42

. If you set relay 2 for key number 9 then you MUST change relay 1 to different key

number even though relay 1 is not used.

1. 

Log-in to programming

2.  Enter 41 then #

3.  Press 1-9 (9 is default setting) then press #

Summary of Contents for QUANTUM QC Series

Page 1: ...ction Code 09 Access Code Digit Function Code 10 Add Card Function Code 11 Delete Card Function Code 12 Clear All Cards Function Code 23 Lock out Count Function Code 24 Alarm Function Code 25 Keypad B...

Page 2: ...t to make changes without prior notice to any products in order to improve reliability function or design PRODUCTS LIMITED WARRANTY If your product does not work properly because of a defect in materi...

Page 3: ...Y ARE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty lasts so t...

Page 4: ...he model number 20 programmable time zones 10 programmable auto unlock schedules and 20 holiday schedules 10 programmable temporary cards and access codes for limited use 10 programmable unlock hold c...

Page 5: ...X1 AUX2 and GND Connect input device such exit switch postal lock etc 8 DOORS1 DOORS2 GND Door Sensor connect to door swicth to monitor door opening and closing 9 RS 485 Slave units connection up to 8...

Page 6: ...n o 6 A B C a b c 2 P Q R S p q r s 7 D E F d e f 3 T U V t u v 8 G H I g h i 4 W X Y Z w x y z 9 J K L j k l 5 SPACE Cancel call Erase incorrect letter or number exit programming CALL ENTER EXCEPT PR...

Page 7: ...amming 2 Enter 01 then 3 Enter directory number 2 3 or 4 digits depending on the setup see function code 19 then see Chapter 3 for keypad layout 4 Enter name up to 16 characters name can be a person n...

Page 8: ...layout 4 Enter the a new tenant phone number up to 16 digit then press or press to keep the existing phone number Return to step 3 to edit another tenant directory Function Code 03 Delete Tenant Direc...

Page 9: ...programming 2 Enter 05 then 3 Enter 0 disable default pr 1 enable then press Function Code 06 Add New Access Code An access code is a keyless entry code to open the door An access code can be programm...

Page 10: ...in system then press 9 Enter 0 no more additional time zone then press and return to step 3 to program another access code 1 add additional time zone then press and return to step 6 exit programming F...

Page 11: ...in to programming 2 Enter 09 then 3 Enter 4 5 6 7 or 8 default setting is 4 digit then press Function Code 10 Add Card 1 Log in to programming 2 Enter 10 then 3 Present the card or keyfob against the...

Page 12: ...then press 9 Enter 0 no more additional time zone then press and return to step 3 to add program another card 1 add additional time zone then press and return to step 6 exit programming Function Code...

Page 13: ...mming 2 Enter 12 then 3 Enter 1 to clear all keyfobs or cards press or to cancel Function Code 13 Set Time 1 Log in to programming 2 Enter 13 then 3 Enter HH in military time MM minute the press Funct...

Page 14: ...RAM buffer The Event RAM buffer can hold 800 2000 events The Events are stored as first in first out FIFO This function code will clear the event buffer 1 Log in to programming 2 Enter 15 then Enter...

Page 15: ...day 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press 8 Enter 1 Relay 1 door 1 2 Relay 2 door 2 3 Both relay 1 and 2 then press 9 Return to step 3 to enter another AUS Function Code 17 Time Zone T...

Page 16: ...e in military then press 7 Enter 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press Return to step 3 to program more time zone Function Code 18 Holiday Zone HLD HLD is t...

Page 17: ...anged to 3 or 4 digits The directory can also be used for direct call 1 Log in to programming 2 Enter 19 then 3 Enter 2 3 or 4 digit then press Function Code 20 AUXIN1 AUXIN1 is used for input device...

Page 18: ...UXIN2 then press Function Code 22 Do Not Disturb If Do Not Disturb is enabled then the calling feature is disabled 1 Log in to programming 2 Enter 21 then 3 Entert 0 disable 1 enable then press Functi...

Page 19: ...ault setting 2 disable system for 60 seconds with no beep 3 call directory 0 9 then press Function Code 25 Keypad Beep Turn the keypad press beep On or Off 1 Log in to programming 2 Enter 25 then 3 En...

Page 20: ...to programming 2 Enter 28 then 3 Enter 01 99 second then press Function Code 29 Unlock Relay 2 Time The amount of time for relay 2 to trigger 1 Log in to programming 2 Enter 29 then 3 Enter 01 99 seco...

Page 21: ...ee Chapter 3 for keypad layout 6 Enter name then press 7 Enter 1 relay 1 door 1 2 relay 2 door 2 or 3 both relay then press 8 Enter time zone set 1 3 then press 9 Enter 00 24 hours 20 see function cod...

Page 22: ...ammed 1 Log in to programming 2 Enter 34 then 3 Enter 0 delete 1 add then press 4 Enter code 01 10 then press 5 Enter 4 8 digit code see digit setting on function code 09 see Chapter 3 for keypad layo...

Page 23: ...be expired after being used a certain amount of times specified 1 10 times in the programming Up to 10 temporary cards can be programmed 1 Log in to programming 2 Enter 35 then 3 Enter 0 delete 1 add...

Page 24: ...ional time zone then press and return to step 8 exit programming Function code 36 Special Card The card can be use to unlock hold open hold and use same code again to lock close door or gate Up to 10...

Page 25: ...ore additional time zone then press and return to step 3 to program another temporary code 1 add additional time zone then press and return to step 8 exit programming Function Code 38 System Acknowled...

Page 26: ...s for relay 2 is set to 8 see function code 41 If you set relay 1 for key number 8 then you MUST change relay 2 to different key number even though relay 2 is not used 1 Log in to programming 2 Enter...

Page 27: ...otely DTMF key 7 6 then press Function Code 43 Do Not Disturb Time Zone If you do not want to be disturbed from someone calling you from the system during certain hours of the days you can create Do N...

Page 28: ...m s relay can be disabled during certain time but the system is still in full operation Maximum 10 disable time zones 1 Log in to programming 2 Enter 44 then 3 Enter 0 9 then pres 4 Enter 0 Delete the...

Page 29: ...Enter relay 1 door 1 then press then press or relay 2 door 2 then press then press Function Code 46 Firmware Version To check the system s firmware version 1 Log in to programming 2 Enter 46 then Func...

Page 30: ...ond delay is plenty of time then press Function Code 49 Edit Existing Access Code Temporary Code and Special Code 1 Log in to programming 2 Enter 49 then 3 Editing an Access Code click here or Editing...

Page 31: ...n code 19 2 Scrolling press 3 or 6 to scroll name then press to call the selected name 5 2 Opening Door Remotely Relay 1 door 1 press 9 Relay 2 door 2 press 8 5 3 Opening Door Using Access Code Tempor...

Page 32: ...t work Swipe the card or keyfob as shown below The card reader antenna is mounted behind the black square window 5 5 Extending Talk Time The talk time timer is set on function code 27 The warning beep...

Page 33: ...2022 8 58 09 AM CHAPTER 6 QWCM Internet IP Module The QWCM Web Based module is included for all IP and VOIP Series Click here for QWCM manual QWCM DEFAULT SETTING IP 192 168 1 230 SUBNET 255 255 255...