Follow these safety precautions when operating the PACER INDUSTRIAL MIXERS Dual arm or Single arm 
mixers. 
 
Installation 
1.  Before operating the machine, read this Owner’s manual carefully. 
2.  Ground the machine properly. Be sure to follow proper grounding and electrical procedures. 
3.  Avoid dangerous environments.  Do not use the machine in a damp or wet environment. 
4.  Use the proper power source.  Refer to the machines designation label located on the back of the machine.  

If it is unreadable call our customer service department (1-888-236-1143) before connection the mixer to a 
power source. 

5.  Avoid  extension  cords.  To  minimize  the  risk  of  circuit  overload,  or  improper  electrical  grounding  do  not 

use extension cords. 

 
Operation 
6.  Ensure the can being mixed is securely clamped. 
7.  Keep customers away from mixing area.  Only trained personnel should operate the mixer. 
 
Maintenance 
8.  Do not get the timer, control panel or wiring wet.  Failure to do so could result in electric shock. 
9.  Clean all surfaces of the machine with soap and water.  Do not use any solvent-based cleaners or thinners. 
10. Disconnect machine from power source before cleaning or servicing mixer. 
11. Be sure to maintain the mixer on a regular basis.  Follow the maintenance procedures on page 8. 

Summary of Contents for Single

Page 1: ...Pacer Dual Pacer Single Arm Mixers Owner s Manual...

Page 2: ...ion 3 Safety Precautions 4 Installation Instructions 5 Electrical Connections 7 Operating Instructions 8 Air driven models 9 Troubleshooting 10 Wiring Diagrams 11 Parts list 13 Ordering Replacement Pa...

Page 3: ...mpletely and save for future reference Machine Models This manual includes instructions and replacement parts information on all models PACER INDUSTRIAL MIXERS Dual arm and Single arm mixers 115V 60 H...

Page 4: ...888 236 1143 before connection the mixer to a power source 5 Avoid extension cords To minimize the risk of circuit overload or improper electrical grounding do not use extension cords Operation 6 Ens...

Page 5: ...top and bottom of each spring 3 Insert a spring and foot assembly into the recess in the bottom of each corner of the Counter Stand castings 4 Plug the power cord into a grounded receptacle see page...

Page 6: ...he floor to apply rubber cement Make sure the boards do not touch the suction cups B Clean the floor directly under the suction cups Clean the contacting surface of the suction cups C Apply rubber cem...

Page 7: ...rface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician if you don t completely understand these grounding instruc tions or if you are not sure whet...

Page 8: ...ff The motor will not start again until it has cooled down Mixing Procedure 1 Turn the clamp handle counter clockwise to open the clamp 2 Place the container to be mixed in the clamp and turn the clam...

Page 9: ...i to reliably operate the machine and must not exceed 200psi Air driven models require no electrical connection Operation Mixing Procedure Air driven models don t have a timer Control the mixing time...

Page 10: ...ified electrician replace timer Broken worn or loose drive belt Visually inspect drive belt and replace if necessary Worn or damaged clamp plate Replace clamp plate Clamp lead screw and or clamp rods...

Page 11: ...Pushbutton Timer Dial Timer 11...

Page 12: ...Optional Safety Cover Switch Single Arm Mixer Optional Safety Cover Switch Dual Arm Mixer 12 Explosion Proof Model...

Page 13: ...Connector block 12 1 PIM 10003 Counterweight pulley 13 1 PIM 10110 Bearing housing cover 14 1 PIM 10011 Breather valve Item Qty Part Number Description 15 2 PIM 10007 Side seal 16 1 PIM 10008 Front s...

Page 14: ...Rollpin 3 16 x 1 50 Clamp Assemblies Item Qty Part Number Description 10 2 PIM 10157 404 Woodruff key 11 1 PIM 10024 Clamp plate right front 12 1 PIM 10025 Clamp plate right rear 13 2 PIM 10124 Lockwa...

Page 15: ...an clip 5 4 PIM 10143 Screw hex head cap 3 8 16 x 1 00 6 4 PIM 10172 Lockwasher split 3 8 7 1 PIM 10033 Drive belt 8 4 PIM 10176 Screw hex head cap 5 16 18 x 7 8 9 4 PIM 10125 Lockwasher split 5 16 10...

Page 16: ...head self tapping 8 x 25 8 2 PIM 10154 Screw pan head thread cutting 8 18 x 50 9 2 PIM 10181 Screw pan head self tapping 4 24 X 5 16 Item Qty Part Number Description 10 1 PIM 10036 Timer knob 12 1 PIM...

Page 17: ...84 Controller 2 2 PIM 10154 Screw pan head thread cutting 8 18 x 50 3 1 PIM 10134 Nut nylock 1 4 20 4 3 PIM 10182 Pushbutton 5 1 PIM 10183 On off switch 6 1 PIM 10168 PB timer plate 7 1 PIM 10118 Flat...

Page 18: ...2 Lockwasher int ext tooth 1 4 Item Qty Part Number Description 13 6 PIM 10171 Screw pan head self tapping 8 x 5 16 type AB 14 6 PIM 10140 Screw flat head self tapping 8 x 50 type AB 15 1 PIM 10120 Fl...

Page 19: ...ylock 5 16 18 6 2 PIM 10147 Screw Hex head 1 4 20 x 1 50 7 2 PIM 10122 Lock washer int ext tooth 1 4 8 1 PIM 10052 Left side brace weld ment PIM 10061 Right side brace weld ment 9 2 PIM 10058 Bumper 1...

Page 20: ...of com mon parts for Dual Safety Covers Item Qty Part Number Description 7 1 PIM 10244 Switch actuator safety cover LS 1 PIM 10255 Switch actuator safety cover RS not shown 8 4 PIM 10133 Nut nylock 8...