9. Hold the barrel at approximately 60° (+ or -20°) angle, rest the tip on a piece of paper and
dispense a small amount of material. This initial dispensing will fill the tip with material.
10. Depress the foot pedal to dispense material.
11. Place barrel in Dispenser Cubby when dispensing operation is
complete.
NOTE:
Condensation may occur in the air hose after extended
use. This is a normal occurrence. To remove the
condensation, disconnect the air hose from the barrel adapter and actuate the dispense
pump. The air pressure will blow the condensation from the air hose.
Adjustment of Dispensing Modes
The Mode Switch is located on the rear panel of the unit. Please refer to the table below for the
settings.
NOTE:
Dispensing at controlled time means dispensing according to set dispensing and interval
times.
2
1
ON
3
4
Mode Switch Status
Item
No.
S1 S2 S3 S4
Function
1 OFF OFF OFF OFF
With pedal switch pressed, dispense continuously,
otherwise it will stop dispensing.
2 ON OFF
OFF
OFF
Be
triggered
once,
dispense at controlled time once.
3
OFF
ON
OFF
OFF
Be triggered once, dispense at controlled time twice.
4 ON ON OFF
OFF
Be triggered once, dispense at controlled time three
times.
5 OFF OFF ON OFF
Be triggered once, dispense at controlled time four
times.
6
ON
OFF
ON
OFF
Be triggered once, dispense at controlled time five times.
7
OFF
ON
ON
OFF
Be triggered once, dispense at controlled time six times.
8 ON ON ON OFF
Be triggered once, dispense at controlled time seven
times.
9 OFF OFF OFF ON
Be triggered once, dispense at controlled time eight
times.
10 ON OFF OFF ON
Be triggered once, dispense at controlled time nine
times.
11
OFF
ON
OFF
ON
Be triggered once, dispense at controlled time ten times.
12 ON ON OFF
ON
Be triggered once, dispense at controlled time eleven
times.
13 OFF OFF ON ON
Be triggered once, dispense at controlled time twelve
times.
©2004 PACE Inc., Annapolis Junction, Maryland
Page 8 of 15