Quick Start Procedure
The MBT 201 systems are very easy to operate. As received from the factory, the system can be quickly
set up for use in standard soldering/desoldering operations. Simply perform the following Quick Start
Procedure to begin system operation.
1. Ensure that the Set-Up procedure has been performed; check for the following:
a) VisiFilter connection to the
AUTO SNAP-VAC
Port on the front panel of the power source.
b) Handpiece cable and air hose connections to the power source.
NOTE
If more than one air-operated handpiece (SX-80, TJ-70 or TP-65) is
connected to the power source, ensure that only one of the Air Hoses is
connected to either the VisiFilter assembly (connected to the
AUTO SNAP-
VAC
Port) or the Controllable
PRESSURE
Port. Attachment to both
simultaneously will cause a deterioration in performance.
a) All handpiece Tip & Tool Stands set up as desired (using instructions enclosed).
b) Proper tips installed in handpieces.
c) Power cord connection between the house AC supply receptacle and the power source.
2. Turn the Power Switch to the "On" ("l") position.
3. Adjust the Variable Temperature Control of each channel with a connected handpiece to the
desired tip temperature.
4. Observe the Channel LEDs. Once stabilized at the set Tip Temperature, the associated LED
will flash at a constant rate.
NOTE
Read the "Operation" section of this manual to utilize the full capabilities of
the system. This is especially important when using large soldering tips.
Refer to the enclosed handpiece manuals for a complete description of
handpiece capabilities.
Operation - Quick Start
21