PEC 013
Page
60
of
71
12/20/13
Programmable Parameters
Faststop Recorder
Parameter Name
Number
Min/Max/Default/Units
Deceleration Rate to Trigger Faststop
Recorder
N064
MIN = 11.2 (mph/sec
2
)
MAX = 55.9 (mph/sec
2
)
DEFAULT = 11.2
(mph/sec
2
)
ON/OFF Requirements
Faststop Recorder
ON
OFF
Faststop Recorder ON
Faststop Recorder OFF
Activate/Deactivate Requirements
Faststop Recorder
Activate
Deactivate
Vehicle deceleration rate is ≥
Deceleration Rate to Trigger Faststop
Recorder
Vehicle deceleration rate is < Deceleration
Rate to Trigger Faststop Recorder