COMPONENT MOUNTING
1
Choose a location to mount the gauge and switch panel. It should
be in reach and in clear view to the driver. Using the bracket as a
template, mark and drill two
3
/
16
diameter holes to secure the
bracket. Do not install the bracket until the electrical and airlines
are connected.
2
Thread sealant or Teflon tape must be applied to all the fitting
threads installed throughout the installation to prevent air leaks.
Installation of the compressor
Install the push to connect fitting into the check valve, then install
the assembly into the compressor head, As shown in photo.
3
The compressor makes an audible pumping noise when activated,
Consider this when choosing a mounting location. The location
should also be in a clean, dry area to maintain long compressor
life. Using the compressor as a template, mark and drill three
3
/
16
diameter holes. Secure the compressor using the fasteners provided.
Thank you and congratulations on the purchase of a Pacbrake basic independent air spring activation kit. Please
read the entire installation manual prior to starting the installation to ensure you can complete the installation once
started. Plan the location and mounting of the control panel, compressor, airline routing and electrical connections
before starting.
BEFORE STARTING: Ensure the kit includes all the items shown in the photo.
1
2
HP10098
IMPORTANT:
This kit includes push-to-connect airline fittings. They require the end of the airline to be
cut cleanly and square to ensure the internal seal will not leak air. The airline must only
be cut with a sharp knife or hose cutter. Using scissors or wire cutters will distort the
airline causing the connection to leak air past the o-ring seal.