pac direct KS12R User Manual Download Page 9

8 - Regular operations of maintenance 

 

Washing the sand filter of your filtration installation :                           

 

Stop the Heat pump 

          Wintering :                                                                           
   Stop and put the heat pump out of tension                                           
 

Stop and put the filtration pump out of tension                        

 

Close the 2 isolating valves nearest of the Heat pump                      

 

Entirely unscrew the 2 connections on the Heat pump and have 

each pipe slip to make leave the openings coming out from the heat 
pump ; the Heat pump gets empty,  wait for the complete emptying. 
(THE EXCHANGER MIGHT BURST IF IT HAS NOT EMPTIED 
COMPLETEY)                                                                                  
 

Put back each pipe to its place and screw again the connections to 

entirely close again (to avoid  little animal’s entry )   Remark :  
supplement the draining of your filtration installation or  call your 
fitter (all your installation must be protected against the freezing) 

 Maintenance : 

 

Make sure that nothing comes to block the gilds radiator, if it’s 

necessary  clean it with a soft brush (no water jet under pressure)                 
 

Make sure that the gilds are right, rectilinear, if it’s necessary 

rectify them with a fine comb                                                 
 

Make sure that the flue of the condensates is not blocked  

 
 
 
 
 
 
 

 

 9

www.pac-direct.com

Summary of Contents for KS12R

Page 1: ...Swimming Pool Heat Pump User manual MODEL KS8R KS12R KS15R KS20R 1 www pac direct com...

Page 2: ...e filtration pump is working At the beginning of the season or when the outside temperature is low you must increase the daily filtration time so that the Heat pump can overcome thermal losses of the...

Page 3: ...risk of overheating Keep out of reach of children and do not to let them play nearby inform them of the dangers of this machine Never introduce a stick or your fingers into the protective grille of t...

Page 4: ...mes wet you might observe a thin layer of white frost on the gilds of the radiator This is normal To avoid a strong thickness of white frost which would prevent the air to circulate through the gilds...

Page 5: ...After starting Ensure that operation is regular if high vibrations occur stop the Heat pump and call your fitter Instructions Careful The first pressure on the key ON OFF gives the authorization of st...

Page 6: ...re desired Adjustment of the stop temperature in cold period Adjustment of the start and stop hour Choosing the heating or the cooling mode On off Defrost forced To adjust the hour Error messages The...

Page 7: ...ton ON OFF Start between 1 second and 4 minutes in the last active mode heating or cooling Go from heating mode to cooling mode or inversely from cooling to heating Press the button MODE Stop for 4 mi...

Page 8: ...to confirm the setting 2 Press Timer on to enter timer setting to start the unit Press key adjust hour number Press Timer on again to adjust minute number Press Timer on once more to confirm the sett...

Page 9: ...emptying THE EXCHANGER MIGHT BURST IF IT HAS NOT EMPTIED COMPLETEY Put back each pipe to its place and screw again the connections to entirely close again to avoid little animal s entry Remark supplem...

Page 10: ...nt in the evaporator E 5 Magnetic ammeter The compressor stops 3 times in 24h because of intensity excess in the compressor Environment problem See DIRECTIONS FOR INSTALLATION AND MAINTENANCE E 6 Comp...

Page 11: ...of the condensates not installed or stopped black plastic conduit prolonged with a flexible pipe of evacuation It s natural these condensates are caused by condensation of the humid air on the gilds...

Reviews: