P3 International Kill A Watt PS P4320 Operating Manual Download Page 8

3. 

Over Current mode

: When the current load presented by the connected appliances exceeds the 

setting on the Max. Amps switch, the unit will switch to Over Current mode. The power will be switched 
off to the 8 outlets. The red LED in the OFF switch will flash. The LCD will display the protected current 
value. The Over Current icon will flash and the audible alarm will sound. Remove the appliance(s) which 
is causing the over current power draw or readjust the Max. Amps value to a higher setting. Then press 
the OFF key and then the ON key to turn the power back on. 

4. 

Abnormal Voltage mode

: When the voltage presented at the wall outlet if over or under the normal 

voltage range, the unit will switch to Abnormal Voltage mode. The power will be switched off to the 8 
outlets. The red LED in the OFF switch will flash. The LCD will display the protected voltage value. The 
Abnormal Voltage icon will flash and the audible alarm will sound. When the AC line voltage delivered 
by the wall outlet returns to a normal range and is stable for at least 3 seconds, the unit will switch back 
to normal mode and restart power immediately. The unit will enter Abnormal Voltage mode if the AC line 
voltage is over normal by 13% or under normal by 18%. The unit will switch back to normal mode when 
the AC line voltage returns to +10% to -15% normal. 

5. 

Over Load mode

: The unit contains dual redundant over load protection circuits; an electronic control 

breaker and a traditional NFB (No Fuse breaker). 

a. 

Electronic control breaker

: When the current load presented by the connected appliances 

exceeds 15 Amps, the unit will switch to Over Load mode. The power will be switched off to the 
8 outlets. The red LED in the OFF switch will flash. The Over Load icon will flash and the 
audible alarm will sound. Remove the appliance(s) which is causing the over load power draw. 
Then press the OFF key and then the ON key to turn the power back on. 

b. 

NFB (No Fuse breaker)

: When the NFB detects an over load condition, it will set and cut off 

power to the unit. This will cut off power to the 8 outlets as well as the LED’s and LCD display 
panel. The unit will be totally without power. Check and remove the appliance(s) causing the 
over load, then press the NFB button to reset the breaker. 

6. 

Ground OK, Wiring OK detection

: When you connect the unit to a wall outlet, the unit will check the 

structure wiring to determine and wire faults. The unit checks the Line, Neutral and Ground wiring. 
Under normal conditions, “Ground OK” and “Wire OK” icons will display on the LCD. If Line or Neutral 
are in the wrong positions, the “Wire OK” icon will disappear. If the Ground wiring is not correct, both 
“Ground OK” and “Wire OK” icons will disappear. 

7. 

Surge Protection

: The unit features a self-test function. If the surge protection circuitry is operating 

properly, the LCD display with indicate with the “Surge OK” icon. If the surge protection has failed, the 
“Surge OK” icon will disappear. 

8. 

EMI Filter

: The unit features a built-in EMI (electro-magnetic interference) filter to reject noise from the 

AC power line. 

9. 

Internal Switch Self Test

: The LCD will flash the “REPLACE” icon and sound an audible alarm if the 

unit detects that the internal relay switch has failed. 

Summary of Contents for Kill A Watt PS P4320

Page 1: ...can protect your valuable electronics and find out what they are actually costing you Simply connect these appliances to the Kill A Watt PS and it will assess how efficient they are while the built in surge protection keeps them safe Advanced features such as over current over voltage and no load detection provide clean safe power to your expensive equipment Check the quality of your power by moni...

Page 2: ...b wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the like Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the product Any mounting of the product should follow the manufacturer s instructions Ventilation Slots and openings in the cabinet...

Page 3: ...f liquid has been spilled or objects have fallen into the product If the product has been exposed to rain or water If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician t...

Page 4: ...stable 2 5 10 or 15A breaker 5 NFB No Fuse Breaker Over Load protection Wall Mount Instructions Optional 1 Use 3 4 inch no 8 screws or similar 2 Space the 2 screws about 9 inches 230mm apart according to the figure Leave about 1 4 inch 5mm of the screw head protruding from the surface 3 Place the unit against the surface with the screw heads fitting into the mounting holes 4 Move the unit downward...

Page 5: ...l go dark and the NO Load icon will flash on the LCD display THIS IS NORMAL If the attached appliance is then turned on the unit will detect a load the ON key will illuminate and the NO Load indicator on the LCD display will disappear 6 Pressing the Volt Amp key will cycle through currently measured voltage Volts current Amps and Maximum Minimum measured values 7 Pressing the Watt PF Key will cycl...

Page 6: ... power will not be applied to the outlets Understanding the No Load Function 1 No Load means no electrical load placed on the unit Either there are no appliances connected to the unit or the appliances connected are turned off and are not drawing any stand by power If a connected appliance is turned off but is still drawing stand by power there is still a load placed on the unit The unit will not ...

Page 7: ...ed Time will be retained 2 This allows the user to take measurements anywhere and relocate the unit to a more convenient location to read the display When the unit is plugged back in the display will become active and will flash as an indicator of power interruption Press any key momentarily to cancel the flashing The accumulated KWH measurement can be retrieved by using the KWH Leakge key The acc...

Page 8: ...reaker When the current load presented by the connected appliances exceeds 15 Amps the unit will switch to Over Load mode The power will be switched off to the 8 outlets The red LED in the OFF switch will flash The Over Load icon will flash and the audible alarm will sound Remove the appliance s which is causing the over load power draw Then press the OFF key and then the ON key to turn the power ...

Page 9: ...If condition persists call a qualified technician This is the abnormal voltage too high or too low protection function 5 No Load icon on the LCD display flashes The unit will power on automatically when the load returns This is the no load protection function to reduce the chance electrical shock or damage 6 No Load icon continues to flash when appliances are connected and turned on Increase the n...

Page 10: ...ion costs shall be borne by the owner and the risk of loss shall be upon the party initiating the transportation All items repaired or replaced thereunder shall be subjected to the same limited warranty for a period of six 6 months from the day P3 ships the repaired or replaced product The warranty does not apply to any product that has been subject to misuse tampering neglect or accident or as a ...

Reviews: