AC Parallel Operation

 

The D2000iS generator has two models that are compatible with each other (Standard and Companion). It is possible to 
connect two D2000iS generators to each other, using a parallel cable kit.

 

•  Connect PARALLEL OPERATION CABLES to two D2000iS generators according to the instructions provided with the 

cable kit. 

•  Make sure the ECO switch is in the same position on both generators. 
•  All electronic devices should be turned “OFF” and disconnected from generators prior to starting generator engines. 
•  Start generator engines. Make sure the green output indicator light comes on for eachgenerator. 
• 

 

•  Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load. 

 
 

Maximum Power in Parallel Operation: 

4.0kVA

 

Rated Power in Parallel Operation: 

3.0kVA

 

 
 
 

Note: 

It is strongly recommended to plug in devices with the 

overloading the generator.

 

Note: 

Most electronic devices require power beyond its rated wattage to start. This additional power is referred to as surge 

watts and usually lasts between 2-3 seconds.  When an electronic device is started, the red overload indicator may come 
on. This is normal. If the light stays on disconnect all electronic devices and stop the engine. Refer to 

“Engine Overload 

Indicator Light” on page 8.

 

 

 

 

OPERATION 

•  A faulty appliance or power cord can create an electric shock. Do not use electronic devices that have a damaged cord 

or plug.

 

•  If an appliance begins to operate abnormally, becomes sluggish, or stalls, turn off and disconnect appliance 

immediately. The appliance may have a fault or its rated load capacity exceeds the power supply of the generator.

 

•  To avoid damage to generator or electronic device, do not connect a load to the generator if its electrical rating exceeds 

that of the receptacle.

 

Only connect electronic devices to the generator that are in good working order and do not 
exceed the rated power supply of the parallel generators or the desired receptacle.

 

WARNING!

 

WARNING! 

Never connect generators that are different models.

 

•  Only connect this generator to another D2000iS Generator or D2000iS Companion Generator

 

•  Only use brands approved parallel operation cable kit to connect generators.

 

•  The parallel cable must be removed if operating only one generator.

 

•  Never disconnect or remove the parallel operation cable while generator is still running.

 

Parallel Box 

Summary of Contents for P2000i

Page 1: ...2 FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference P1PE INVERTER GENERATOR P2000i P2000iS P2500i P2500iS User Manual...

Page 2: ...ctrical System 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How toStop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery 1...

Page 3: ...s Generator specification MODEL P2000i P2000iS P2500i P2500iS Rated AC Voltage V 110V 120V 220V 230V 240V Rated Frequency Hz 50Hz 60Hz Rated Power kW 1 6 1 6 2 0 2 0 Starting Power kW 2 0 2 0 2 5 2 5...

Page 4: ...Using a generator indoors WILL KILL YOU INMINUTES Carbon monoxide gas isa poisonous odorlessgas thatcan causeheadache confusion fatigue nausea fainting sickness seizures ordeath Ifyou start toexperien...

Page 5: ...thegenerator and or connected electricaldevices WARNING When adding or draining fuel unit should be turned off for at least 2 minutes to cool before removing fuel cap If unit has been running then the...

Page 6: ...uitinterrupter GFCI orRCD inadamporhighlyconductivearea suchasmetaldeckingor steel work Neverplugelectronicdevicesintogeneratorhaving frayed worn orbare wires Never touchbare wiresormake contact with...

Page 7: ...Oil Warning Light K Overload Indicator Light P1 120VACOutlet Q ParallelOutlets R Ground Terminal D Outer Casing Side Panel E Handle Grip F Air Vent G FuelCap H Recoil Starter L AC Pilot Light M 3in1S...

Page 8: ...gine Overload Indicator Light Iftheengineoverloadindicatorlightcomeson thegenerator swattage amperagecapacityhasbeenexceededbyconnectedelectrical devicesorbyapowersurge Whenthisoccurs thegreenACPilot...

Page 9: ...nit automatically determines the generator s properengine speed basedon the connectedelectronicload Thisresults in superior fueleconomyand reduces noise When the ECO switch is turned to the OFF positi...

Page 10: ...used to connect the generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AWG American Wire Gage copper wire The wire connects to the terminal between the...

Page 11: ...tightly Do not smoke when adding fuel Turn cap counterclockwise to remove provide space for fuel expansion Neverhandlethegenerator electronicdevices oranycordwhilestandinginwater whilebarefoot orwhenh...

Page 12: ...addthespecifiedamountof4 Cycleengineoil SAE10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick and securely tighten b...

Page 13: ...nt to the ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as e...

Page 14: ...tacles are in good condition Make sure all electronic devices are turned OFF before plugging them into thegenerator 2 Start engine 3 If the attached load is small turn the ECO switch to the ON positio...

Page 15: ...recommended to check the gravity level of the electrode at least once per hour with a hydrometer to preventovercharging and totest thebattery s condition Be careful to follow thehydrometermanufacture...

Page 16: ...onic device is started the red overload indicator may come on Thisisnormal Ifthelightstaysondisconnectallelectronicdevicesandstoptheengine Referto EngineOverload Indicator Light on page8 OPERATION A f...

Page 17: ...ial Arm Saw 2000 2000 Electric Drill HP 5 4 Amps 600 900 Don t Overload Generator Make sure you can supplyenough rated watts forallelectronic devices connectedto the generator Rated wattsreferto the p...

Page 18: ...conditions Service Spark Plug 12 Months 300 hr Use Clean Fuel Filter Replace if necessary Check Crankcase Breather Hose for cracks or damage Replace if necessary De carbonize cylinder head See dealer...

Page 19: ...ebrush Check the electrode gap and slowly adjust to 0 7 0 8mm 0 028 0 031 in ifnecessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft lb Ifsparkplug isworn replace only with anequivalent r...

Page 20: ...o collect used oil Allow oil to drain completely Return generator to a levelsurface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall outer casing...

Page 21: ...uldbedamp butnotdripping Remove screws then remove shown area of outer casing Check the muffler screen and spark arrester for damage If damaged replace with Our replacement parts Install the outer cas...

Page 22: ...air cooling slots Remove any debris if obstructed Store indoors and use a protective cover to protect from dust FUEL Forshort termstorage addfuelstabilizertopreventstalefuelfromcausingacidandgumdepos...

Page 23: ...Start generator engine and letitrun untilit stops and allremaining fuel isconsumed Do not connect electronic devices to generator during thisprocess Remove outer casing screws then remove outer casing...

Page 24: ...epartment 5 Contact servicedepartment Enginewillnotstart shutsdown during operation orstartsandrunsrough 1 3 in 1 switch set to OFF 4 Out of fuel or Stale fuel 5 Sparkplugwiredisconnectedfrom spark pl...

Page 25: ...your local authority or recycling centre Certain products contain batteries which should not be disposed of in your domestic waste You MUST recycle batteries in accordance with your local authority or...

Page 26: ...es 97 68 EC Non Road Mobile MachineryDirective 2000 14 EC Outdoor Noise Directive 2004 108 EC ElectroMagneticCompatibilityDevice 2006 42 EC Machinery Directive P2000i P2000iS 1 6kW P2500i P2500iS 2 0k...

Page 27: ...oad PembrokeDock Pembrokeshire SA724RW UK Telephone 44 0 1646687880 Fax 44 0 1646686198 Website www p1pe co uk To register your machine for the manufacturer s warranty please visit http www p1pe co uk...

Page 28: ...P1PE Position One Power Equipment IsaacWay PembrokeDock Pembrokeshire SA72 4RW www p1pe co uk www p1pe co uk...

Reviews: