P+P 90287 User Operating Instructions Manual Download Page 2

USE OF THE LINE WITH 2 PERSONS 

 
The HLL has also been tested and approved 
two-person use - for fall arrest.  This was 
achieved by loading the centre of the line with 
26kN (2650kg).  To ensure the safety of two 
users on the HLL, the minimum clearance 
values given below must be adhered to at all 
times. 
 
 

HLL position above user’s 
foot level 

2.0m 1.25m  0.0m 

MINIMUM clearance 
required below user’s feet. 
Ensure that anchor points 
are adequate, at least 30kN. 

8.0m 8.75m  10.4m 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2

P+P HORIZONTAL LIFELINE (HLL) 

 
The HORIZONTAL LIFELINE has been CE 
marked by P+P Ltd to 89/686/EEC using the 
procedures described in BSEN 795:1997 for 
class C devices.  Certified by Approved Body: 
SATRA, Safety Product Centre, SATRA 
House, Rockingham Road, Kettering, 
Northants, NN16 9JH, UK.  Identification No: 
0321. 
 
P+P recommends that all PPE equipment is 
personal issue, all documentation relating to it, 
is kept on file until the item is withdrawn from 
service. 
 
An EN 795:1997 class C device is described 
as an anchor line.  It has been subjected to 
dynamic tests using a non shock absorbing 
lanyard and a 100kg mass in a 4m fall.  The 
P+P line has also been tested with a static load 
of 36kN without failure. 
 

Summary of Contents for 90287

Page 1: ...95 1997 Class C Supplied by Pammenter Petrie Limited PAMMENTER PETRIE LIMITED 140 146 Brearley Street Hockley Birmingham B19 3XJ Tel 44 0 121 359 4561 Sales Tel 44 0 121 503 5860 Training Fax 44 0 121...

Page 2: ...LIFELINE HLL The HORIZONTAL LIFELINE has been CE marked by P P Ltd to 89 686 EEC using the procedures described in BSEN 795 1997 for class C devices Certified by Approved Body SATRA Safety Product Cen...

Page 3: ...me You must be certain that all operatives are in restraint at all times with no potential fall FITTING INSTRUCTIONS 1 When the assembly is at the required location remove the short fixed 50mm webbing...

Page 4: ...if this happens the webbing will jam Should this happen it will be necessary to release the webbing and start the tensioning operation again see releasing operation 5 When tensioning is complete posi...

Page 5: ...d anchor loads in the event of a fall 3 Ensure that harness lanyard attachments karabiners etc are free from sharp edges or burrs 4 Ensure that anchor points are adequate at lease 15kN 30kN for 2 pers...

Page 6: ...d installation information please contact P P IMPORTANT Please note that the test results were achieved using P P Chunkie Fall Arrest Lanyards and a 100kg 16st mass therefore clearances for persons ov...

Page 7: ...The Horizontal Lifeline should also be examined before every use by the user installer particular attention being paid to the following Webbing check for cuts cracks tears abrasion and scorch marks bu...

Reviews: