12
MAN 9058634 EN V1
P. Lindberg A/S
Sdr. Ringvej 1
www.p-lindberg.dk
Tel.: +45 70 21 26 26
DK-6600 Vejen
e-mail: salg@p-lindberg.dk
Storage
Store the indirect air heater where there is not too much dust in the air and where
there is no risk of the equipment coming into contact with corrosive vapours.
Store the indirect air heater in its original packaging together with the manual.
Maintenance
WARNING:
ALWAYS make sure that the indirect air heater is turned off, let it cool and unplug it
before performing any maintenance on the equipment.
Use only original spare parts.
Maintenance tasks
Fuel tank
: Rinse after every 200 operating hours.
Intake filter
: Wash with soap and dry after every 500 operating hours or as required:
-
Remove the screws on the side of the indirect
air heater.
-
Remove the top shield.
-
Remove the fan guard.
-
Wash the filter and reinsert/replace it.
-
Replace the fan guard and the top shield.
Air filter and fluff filter
: Replaced every 12
months or after 500 operating hours:
-
Remove the screws on the side of the indirect air heater.
-
Remove the top shield.
-
Remove the fan guard.
-
Remove the cover.
-
Replace the filters.
-
Replace the cover.
-
Replace the fan guard. Replace top shield.
Air filter
Intake filter
Cover
Fluff filter