SPECIFICATION / REPLACEMENT PARTS

GLUEBOARD REPLACEMENT

BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE 

MAINS SUPPLY.

The glueboard should be replaced every month with a genuine 

glupac

® 

 glueboard.  Use of 

non-approved glueboards may invalidate your guarantee.  IND35

 comes supplied with discreet 

black glueboards with printed grids for simple insect evaluation and monitoring.

  

To replace the glueboard…

 

1. Swing the front guard open.

 

2. Remove the protective release paper from the new 

glupac

® 

 glueboard.

 

3. Position the top of the 

glupac

® 

 glueboard in position behind the two locating pins, 

 

   then carefully drop the horizontal face of the board into position.

Always ensure the selected genuine 

glupac

® 

 glueboards are compatible with your unit, 

available from your pest control operator or P+L Systems Ltd.

TUBE REPLACEMENT

TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT 

THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

To ensure the efficiency of IND35 in catching flying insects, the Synergetic

®  

tubes should be 

replaced annually.  After twelve months the phosphor coating that emits the correct wavelength 

of UV light has burnt away and the UV output is diminished substantially. 

To replace the UV tubes…

 

1. Swing the front guard open.

 

2. Gently rotate the tube through 90º.

 

3. Pull the tube forward until it becomes free from the tube holder.

 

4. Reverse the process with the new Synergetic

®  

 tube.

 

5. Dispose of the used UV tubes in conjunction with local regulations.

STARTER REPLACEMENT

STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING 

THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

The starters provides an extra spark to initially light the UV tubes.  Starters wear out and should be 
replaced at the same intervals as the UV tubes.

To replace the starters…

 

1. Swing the front guard open.

 

2. Rotate the starter anti-clockwise.

 

3. Pull the starter free from the unit.

 

4. Reverse the process with the replacement starter.

Unit  

IND35 

Voltage  

230V   ~   50Hz 

Dimensions(mm)  470 x 230 x 130  

               

Coverage 

80 Sq. Meters 

Weight  

5.0Kg  

Light Output 

30W  

Tubes 

 

2 x TGX15-18S 

 

Starter   

2 x I154   

Glueboards (x6) INF212 

(Black) 

Starter Replacement

Glueboard Replacement

1

2

P+L Systems

Sterling House

Grimbald Crag Close  

Knaresborough

North Yorkshire

HG5 8PJ

UK

T +44 (0)800 988 5359

F +44(0)1423 863 497  

W www.pandlsystems.com

E [email protected]

WEEE Compliance No. 01576542

C

2013

P+L Systems Ltd

Information provided on these instructions is modified and 

updated from time to time.  This is due to the constant 

redevelopment of our products.  As such, it is not intended that 

you should rely on it or that it should form part of any contract.  

Tube Replacement