![P+L Systems INSECT-O-CUTOR Focus Series Instructions Download Page 2](http://html1.mh-extra.com/html/p-l-systems/insect-o-cutor-focus-series/insect-o-cutor-focus-series_instructions_3074237002.webp)
Catch Tray & Guard RemovalCatch Tray & Guard Removal
SPECIFICATION / REPLACEMENT PARTS
Unit
F1
Voltage
230V ~ 50Hz
Dimensions(mm) 268 x 300 x 115
Coverage
45 Sq. Meters
Weight
4.1 Kg
Light Output
11W
Tubes
1 x TGX11
Starter
N/A
Unit
F2
Voltage
230V ~ 50Hz
Dimensions(mm) 360 x 300 x 115
Coverage
90 Sq. Meters
Weight
4.6 Kg
Light Output
22W
Tubes
2 x TGX11
Starter
N/A
MOUNTING FIXING CENTRES
METHOD
F1
F2
Wall
130mm
216mm
Suspended 258mm
345mm
CATCH TRAY AND FRONT GUARD REMOVAL
To remove the front guard, the catch tray must first be removed as shown to the right. The
front guard is connected to the power supply of the unit via a hidden switch. By removing
the front guard the connection is broken and power is cut to the unit. This ensures safe
access to the unit for servicing and cleaning.
NB - WHEN REPLACING THE FRONT GUARD BACK INTO F1 AND F2, ENSURE IT IS PUSHED FULLY
INTO POSITION AND THAT POWER IS RESTORED TO THE UNIT.
NB - THE FRONT GUARD CAN ONLY BE RELEASED ONCE THE CATCH TRAY IS REMOVED
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of the Focus range in catching flying insects, the UV tube(s) should
be replaced annually. After twelve months the phosphor coating that emits the correct
wavelength of UV light has burnt away and the UV output is diminished substantially.
To replace the UV tube(s)…
1. Remove the catch tray.
2. Remove the front guard.
3. Pull the tube away from the tube holder.
4. Dispose of the used UV tube in conjunction with local WEEE regulations.
KILLING GRID REMOVAL
REMOVAL OF THE KILLING GRID SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY,
AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To help with servicing and cleaning, the killing grid within the Focus range can be removed.
To remove the killing grid...
1. Remove the catch tray.
2. Remove the front guard.
3. Remove the tube(s).
4. Pull the killing grid forward, to release it from the plastic clips.
5. Pull the killing grid down to free it from the unit.
2.
Catch Tray & Guard Removal
Tube Replacement
2.
1
R2 01/14
WEEE Compliance No. WEE/GF0661QR
C
2014
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
Catch Tray & Guard Removal
Killing Grid Removal