P+L Systems INSECT-O-CUTOR Focus Series Instructions Download Page 2

Catch Tray & Guard RemovalCatch Tray & Guard Removal

SPECIFICATION / REPLACEMENT PARTS

Unit  

F1

Voltage  

230V   ~   50Hz

Dimensions(mm)  268 x 300 x 115
Coverage 

45 Sq. Meters

Weight  

4.1 Kg 

Light Output 

11W 

Tubes 

 

1 x TGX11 

Starter  

N/A

Unit  

F2

Voltage  

230V   ~   50Hz

Dimensions(mm)  360 x 300 x 115
Coverage 

90 Sq. Meters

Weight  

4.6 Kg 

Light Output 

22W 

Tubes 

 

2 x TGX11 

Starter  

N/A

MOUNTING FIXING CENTRES
METHOD 

 F1 

 F2

Wall 

 130mm 

 216mm

Suspended 258mm 

  345mm

CATCH TRAY AND FRONT GUARD REMOVAL

To remove the front guard, the catch tray must first be removed as shown to the right.  The 

front guard is connected to the power supply of the unit via a hidden switch.  By removing 

the front guard the connection is broken and power is cut to the unit.  This ensures safe 

access to the unit for servicing and cleaning.

NB - WHEN REPLACING THE FRONT GUARD BACK INTO F1 AND F2, ENSURE IT IS PUSHED FULLY 

INTO POSITION AND THAT POWER IS RESTORED TO THE UNIT.

NB - THE FRONT GUARD CAN ONLY BE RELEASED ONCE THE CATCH TRAY IS REMOVED

TUBE REPLACEMENT

TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER 

ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

To ensure the efficiency of the Focus range in catching flying insects, the UV tube(s) should 

be replaced annually.  After twelve months the phosphor coating that emits the correct 

wavelength of UV light has burnt away and the UV output is diminished substantially. 

To replace the UV tube(s)…

 

1. Remove the catch tray.

 

2. Remove the front guard.

 

3. Pull the tube away from the tube holder.

 

4. Dispose of the used UV tube in conjunction with local WEEE regulations.

KILLING GRID REMOVAL

REMOVAL OF THE KILLING GRID SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, 

AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

To help with servicing and cleaning, the killing grid within the Focus range can be removed.  

To remove the killing grid...

 

1. Remove the catch tray.

 

2. Remove the front guard.

 

3. Remove the tube(s).

 

4. Pull the killing grid forward, to release it from the plastic clips.

 

5. Pull the killing grid down to free it from the unit.

2.

Catch Tray & Guard Removal

Tube Replacement

2.

1

R2 01/14

WEEE Compliance No. WEE/GF0661QR

C

2014

P+L Systems Ltd

Information provided on these instructions is modified and 

updated from time to time.  This is due to the constant 

redevelopment of our products.  As such, it is not intended that 

you should rely on it or that it should form part of any contract.  

Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ      UK

T  +44 (0)800 988 5359
F  +44 (0)1423 863 497
W  www.pandlsystems.com
E  [email protected]

Catch Tray & Guard Removal

Killing Grid Removal