background image

8

STEP 2: COMPLETE ELECTRICAL CONNECTION

1

Install female connector (supplied) to end of 
power cable (refer to section 6.1)

2

Once connection is complete, push the female 
connector into the male connector on the end of 
the fixture until firmly engaged.

WARNING

Ensure that the strain relief is properly fitted.  
The contact can become damaged and water 
ingress problems may arise if this is not the case.

3

Switch on the mains voltage.

ATTENTION

In the event that multiple fixtures are mounted 
consecutively, the distance between each
fixture must be a minimum of 4 in. (10 cm)

10 cm

10 cm

4 in

(10 cm)

4 in

(10 cm)

 INITIAL  STARTING

Switch on the mains voltage as a function test. See 
Section 7 Troubleshooting if the fixture fails to light up.

MAINTENANCE, ENVIRONMENT 

 

AND DISPOSAL

WARNING

• Switch off the mains voltage before commencing 

maintenance work.

• Do not open or disassemble the product. Opening the 

product can prove hazardous and will void the warranty.

ATTENTION!

In the event that the product is defective or damaged, 
contact the dealer from whom you purchased the 
fixtures, or PL Light Systems directly. Never switch on 
a defective or damaged fixture.

• Check the product at regular intervals for build-up 

of dust and dirt. Clean the product if necessary. 
Contamination can lead to overheating and reduced 
performance.

• Clean the fixture with a dry or slightly damp cloth. 

Ensure that the glass lens (section 2.2, #2) is 
always clean.

ATTENTION!

• Never clean the product with corrosive cleaning 

agents, abrasives or other aggressive liquids.

• Protect the male end of the Wieland connector 

(section 2.2, #1) against the ingress of water when 
no female connector (section 2.2, #6) is attached.

• Only use a vinegar and water solution (1:100 ratio) 

to remove build-up of limescale on the lens.

• In the event that the product is stored, it must be 

kept in a dry, clean environment with an ambient 
temperature of -20 ~ 50°C

• This symbol on the material, accessories 

or packaging indicates that this product 
may not be discarded as household waste. 
Dispose of the equipment through a 
recycling centre that handles electronics 
and electrical appliances within Canada 
and the United States of America which 
use separate collection systems for used 
electronics and electrical appliances. 
By disposing of the equipment in the 
proper way, you will be helping to prevent 
possible risks to the environment and 
public health, which might otherwise 
be caused by improper handling of 
the discarded equipment. Recycling of 
materials contributes to the conservation 
of natural resources. Therefore, please do 
not dispose of your old electronics and 
electrical appliances via household waste.

Summary of Contents for HORTILED Top

Page 1: ...HORTILED Top EN User and installation manual...

Page 2: ......

Page 3: ...mination of horticultural crops For other applications in professional horticulture please contact P L Light Systems Any use other than the approved intended use described above is considered unintend...

Page 4: ...type sticker 120 277 V AC 50 60 Hz grey connector 347 480 V AC 50 60 Hz green connector Power Draw Max 320 W Power Factor 0 95 Flux with R B LB 860 mol s Efficiency with R B LB 2 7 mol J Colour Spect...

Page 5: ...exceptional uniformity of the light onto the crop 80 distribution 150 distribution 2 2 MAIN COMPONENTS 2 5 3 4 1 2 5 3 4 4 6 1 Parts list 1 Wieland Connector Male 2 Glass Lens 3 Housing 4 Mounting Bra...

Page 6: ...ted outside of the recommended ambient temperature guidelines 4 INSTALLATION 4 1 PREPARATIONS FOR INSTALLATION 1 Switch off the mains voltage 2 Refer to your light plan Arrange boxed light fixtures on...

Page 7: ...ide brackets not supplied as shown below OPTION C 1 Place the fixture with the glass lens facing down on a cushioned surface to prevent damage 2 Secure two M6 thread fasteners not supplied directly to...

Page 8: ...Clean the product if necessary Contamination can lead to overheating and reduced performance Clean the fixture with a dry or slightly damp cloth Ensure that the glass lens section 2 2 2 is always cle...

Page 9: ...gth N L Y 40 35 X 8 8 ATTENTION The wire should have a diameter of 0 5 to 1 5 mm2 3 Push the wire into the correct connection Green yellow Blue N L N L L L Brown L ATTENTION In the event that a plug i...

Page 10: ...fied value range Reset the fixture by disconnecting the mains voltage from the fixture for more than 5 seconds and then reconnecting In the event that the fixture switches off again lower the ambient...

Page 11: ...11...

Page 12: ...2016 PL Light Systems HortiLED Top User Guide 11 19 P L Light Systems 4800 Hinan Drive Beamsville Ontario Canada L0R 1B1 T 905 563 4133 1 800 263 0213 toll free E info pllight com www pllight com...

Reviews: