P.I.T. POG900-P2 Instruction Manual Download Page 6

Self-Priming Pump

5

Turn switch 12 to position “I”. The pump will 
start (when the tank pressure is below the 
pressure switch setting).
Close the shut-off valves in the discharge line 
when there is no air in the water 

 owing out of 

the pump.
The pump will build up the required pres-
sure and, after the cut-off pressure has been 
reached, it will shut off automatically.
The pump turns on and off automatically - as 
the water supply is consumed and when the 
tank is 

 lled.

Note! 

The cut-in and cut-out pressures are 

preset at the factory and cannot be changed 
in the field. Self-adjusting the pressure can 
lead to product failure. If cases of self-adjust-
ment are identified, the product is removed 
from the warranty. If necessary, additional ad-
justment should be carried out by a specialist.
by the service center.
A thermal switch is installed at your pumping 
station to prevent overheating of the pump 
electric motor and its failure.

Note!

 Periodic shutdown and reclosing of the 

station (with constant water consumption) in 
the absence of visible malfunctions (extrane-
ous noise, drop in supply pressure, etc.) are 
signs that the thermal switch has tripped. This 
indicates unfavorable operating conditions: 
high temperature of the ambient air or inlet 
water; being in direct sunlight; prolonged sig-
ni

 cant water consumption, causing the pump 

to run continuously.
At the end of use, turn off the station by mov-
ing the switch 12 to the “0” position. Remove 
the plug from the socket.
Before long-term storage of the station, com-
pletely empty the tank and pump from water 
by draining the water through the nozzle 14.

Attention!

 ALWAYS relieve pressure before 

disconnecting hoses by turning on the nearest 
valve.

Possible problems and malfunc-
tions

The station does not start:

 

There is no mains voltage. 

Check cable, 

plug, connectors, fuse.

 

Overheating of the engine due to high 
temperature of the pumped liquid.

 Elim-

inate the cause of overheating and allow 
the engine to cool down.

 

Overheating of the engine due to 
blocked ventilation openings.

 Eliminate 

the cause of overheating and allow the en-
gine to cool down.

 

The residual current device has tripped.

 

Consult a quali

 ed electrician if the residu-

al current device trips again.

 

Defective engine.

 Contact the service 

center.

Insufficient pressure generated by the 
pumping station:

 

There is not enough water in the suc-
tion line. 

Ensure there is water in the suc-

tion line.

 

The suction line is not tight.

 Check all 

seals and connections on the suction line.

 

The suction lift is too high.

 Reduce the 

suction lift. The suction head must be sub-
tracted from the head.

 

Leakage between pump hydraulics and 
motor.

 Contact the service center.

 

The pump is clogged or defective.

 Flush 

the hydraulic end of the pump with clean 
water.

 

Air in the pump or suction pipe.

 Fill the 

pump with water. If the suction line has a 
non-return valve, 

 ll it with water.

 

Changed pressure switch settings Con-
tact the service center.

 

The suction line rests against the bot-
tom of the tank.

 Fix or shorten the suction 

line.

The pump does not turn off:

 

Defective On / Off switch.

 Contact the 

service center.

Maintenance and Cleaning

 

All maintenance work must be carried 
out with the cable disconnected from 
the mains.

During operation, the pumping station does 
not require any maintenance.
To exclude an accident, it is recommended 
from time to time to check the maximum head 
and energy consumption, as well as the air 
pressure in the accumulator (for this, turn off 
the pump and drain the water from the pres-
sure line). A decrease in the maximum head 
indicates wear, while an increase in energy 
consumption indicates the presence of me-
chanical friction in the pump.
If you 

 nd these or other changes in the oper-

ation of the pump, contact the service center.

Service

 

Have your power tool repaired only by 
quali

 ed personnel and only with origi-

nal replacement parts. This ensures the 
safety of the power tool.

The list of authorized service centers can be 
viewed on the of

 cial website of P.I.T. by the 

Summary of Contents for POG900-P2

Page 1: ......

Page 2: ...Self Priming Pump 1 ...

Page 3: ...ply pull the plug not the cable Be careful not to pinch the power cord or rub it against sharp edges Install the device in a rack and over fill proof position The mains voltage must correspond to the voltage specified in the technical specifications Protect the appliance from rain and moisture Water penetration into the appli ance increases the risk of electric shock Do not point the water jet direc...

Page 4: ...on for any country house Product Features The numbering of the product features refers to the diagram of the power tool on the graph ics page 1 Power cable 2 Pressure gauge 3 High pressure connection tank 4 High pressure hose 5 High pressure connection pump 6 Water inlet 7 Filling hole 8 Water outlet connection 9 Tank accumulator 10 support 11 Pump 12 Switch 13 Pressure switch 14 Drain hole with p...

Page 5: ... pump in order to prevent air pockets from forming A sufficient water supply must be ensured and the end of the suction line must always be submerged Discharge line connection Attention The discharge line must be in stalled in such a way that it does not exert any mechanical stress or stress on the pump All threaded connections must be sealed with sealing tape to prevent water leakage All parts of ...

Page 6: ...inate the cause of overheating and allow the engine to cool down Overheating of the engine due to blocked ventilation openings Eliminate the cause of overheating and allow the en gine to cool down The residual current device has tripped Consult a qualified electrician if the residu al current device trips again Defective engine Contact the service center Insufficient pressure generated by the pumpi...

Page 7: ...he signature of the buyer shall be accepted for warranty repair 4 Warranty repair is not performed in the fol lowing cases damage to the pumping part or its parts as a result of the pump running dry without water or during prolonged operation with a closed pressure pipeline in the absence of a Warranty Certificate and a Warranty Card or their incorrect execution with failure of both a rotor and a s...

Page 8: ...rvice center The owner of the tool entrusts the diagnostic procedure to be conducted in the service cen ter in his absence Do not operate the electric machine when there are signs of excessive heat sparking or noise in the gearbox To determine the cause of the malfunction the buyer should contact the warranty service center Malfunctions caused by late replacement of carbon brushes of the engine ar...

Page 9: ...м Перед началом работы с прибо ром проверяйте сетевой шнур и штепсельную вилку на наличие по вреждений Все электрические соединения долж ны находиться в защищённом от за топления месте Неподходящие электрические уд линители могу т представлять опасность Вне помещений следует использовать только допущенные для использования и соответственно мар кированные электрические удлинители с достаточным попе...

Page 10: ...ой воды При первом запуске насоса необхо димо обеспечить его полное запол нение водой не допускается работа насоса без расхода воды Не допускается попадание воздуха во всасывающую магистраль Во избежании замерзания необходи мо полностью слить воду из насоса а также всасывающей и напорной магистралей Описание продукта и услуг Прочтите все указания и инструк ции по технике безопасности Несоблюдение ...

Page 11: ...роверьте давление воздуха в баке Проверьте давление в ниппеле Давле ние должно быть 1 5 5 атмосферы При недостаточном давлении увеличьте его при увеличенном стравите Примечание Несоответствие давления указанной величине может привести к выходу мембраны бака из строя Данная неисправность условиями гарантии не под держивается Установите станцию на ровную горизон тальную поверхность и закрепите через...

Page 12: ...и предохранителей и подключе ние к питающей электросети должен вы полнять квалифицированный электрик Насос разрешается подключать только к розеткам с защитным контактом кото рые надлежащим образом установлены заземлены и проверены Заполнение водой Выкрутить пробку заливного отверстия Заполнить водой всасывающую трубу и насосную часть через заливное отвер стие После того как вода заполнит насосную ...

Page 13: ...сывающей трубе Заполните насос водой Если всасывающий трубопровод с обратным клапаном заполните его водой Изменились настройки реле давле ния Обратитесь в сервисный центр Всасывающий трубопровод упира ется в дно резервуара Закрепите или укоротите всасывающий трубопровод Насос не выключается Неисправен переключатель Вкл Выкл Обратитесь в сервисный центр Техобслуживание и сервис Техобслуживание и оч...

Page 14: ...вой организации и подписью покупа теля 4 Гарантийный ремонт не производится в следующих случаях повреждение насосной части или ее ча стей следствии работы насоса всухую без воды или при длительной работе с закры тым напорным трубопроводом при отсутствии гарантийного свидетель ства и гарантийного талона или неправиль ном их оформлении при совместном выходе из строя якоря и статора электродвигателя ...

Page 15: ...ых выше условий гарантийного обслуживания владельцу сообщается после проведения диагностики в сервисном центре Владелец инструмента доверяет проведе ние диагностики в сервисном центре в свое отсутствие Запрещается эксплуатация электроинстру мента при проявлении признаков повы шенного нагрева искрения а также шума в редукторной части Для выяснения причин неисправности покупателю следует обра титься...

Page 16: ... the Warranty Card the boxes shall be filled out by a seller and to affix the seal of the trade organization in the Guarantee Certificate and the Warranty Card Warranty By this Warranty Certificate P I T company guarantees the absence of defects of the production nature In the event any of the above defects are detected during the warranty period the specialized P I T service centers shall repair the ...

Page 17: ...тийного талона графы Заполняются продавцом и простановки печати торговой организации в гарантийном свидетельстве и гарантийных талонах Гарантия На основании данного гарантийного свидетельства компания Р I Т гарантирует отсутствие дефектов производственного характера Если в течение гарантийного срока в Вашем изделии обнаружатся указанные дефекты то специализированные сервисные центры Р I Т бесплатн...

Page 18: ...e_______________________________ Serial Number___________ Sale Date ____________20__ Place of Seal Filled out by a Seller WARRANTY REPAIR CARD Date of Acceptance for Repair _______20___ Application for Repair ___________________ Customer _____________________________ Phone Address ________________________ Cause of Application_____________________ Date of Receipt from Repair ____________20__ The To...

Page 19: ...ace of Seal Заполняется продавцом КАРТА ГАРАНТИЙНOГO РЕМОНА Дата приема ремонт _______20___ Заявка на ремонт ___________________ Заказчик _____________________________ Телефон адрес ________________________ Причина обращения_____________________ Дата получения от ремонта ____________20__ Инструмент проверен в моем присутствии____________ Заказ заполняется в Сервисном Центре Подпись Наименование___...

Page 20: ......

Reviews: