Summary of Contents for OWG 4070

Page 1: ...RIAL TYPE COOKER GAS WOK USER S MANUAL Web adresimiz www oztiryakiler com tr e mail oztiryakiler oztiryakiler com tr BU BÖLÜME YETKİLİ SERVİS BANDROLU YAPIŞTIRILACAKTIR 1783 AUTHORIZED SERVICE BANDEROLE WILL BE AFFIXED AT THIS AREA YEAR OF MANUFACTURE SERIAL NO Our Web address PRODUCTION ADDRESS Beylikduzu Eski Hadimkoy Yolu 1 Km Buyukcekmece Istanbul TURKEY Tel 0090 212 886 78 00 8 Lines Fax 0090...

Page 2: ...ODUCTION 4 TECHNICAL FEATURES 5 LABEL AND WARNING SIGNS 6 7 DETAILS RELATED TO SAFETY 8 HANDLING AND RE LOCATION 9 10 INSTALLATION OF DEVICE 11 GENERAL DIMENSIONS 12 DEVICE USE 13 CLEANING AND MAINTENANCE 14 CONVERSION TO OTHER GASES 15 WARRANTY CONDITIONS ...

Page 3: ...re confused or you don t have enough information please get in touch with authorized service by phone Please keep in mind that if the service personnel is delayed at your site related expenses and delay costs will be charged to you on hourly basis We hope that you will get the best performance from our product Dear User Thank you for purchasing our appliance and for your reliance upon our company ...

Page 4: ...URES YOUR MODEL OWG 4090 OWG 8090 OWG 4070 OWG 8070 OVERALL DIMENSIONS mm 400x900x280 800x900x280 400x700x280 800x700x280 THERMAL POWER KW Hİ ΣQN 14 28 14 28 TYPE А1 А1 А1 А1 GAS INPUT inch R R R R NET WEIGHT Kg 4 15 ...

Page 5: ...LABEL AND WARNING SIGNS Figure OWOGD 12090 5 15 HOT SURFACE SAMPLE LABEL PRODUCT NAME MODEL TYPE SERIAL NUMBER PRODUCTION DATE ...

Page 6: ... petro chemical products wood plastic materials cutting blocks curtains etc should not be around the area of operation of the device You may use our devices adjacent to our other products in the same series Do not clean with pressurized water This device must be installed in compliance with current regulations and used only in a well ventilated area Prior to the installation and use of the device ...

Page 7: ... gas valves and electrical switches without panicking and use a fire extinguisher Never use water to put out the flame The water will cause the flame to spread more rapidly The smell of gas means a sign of gas leakage Under those circumstances turn of the unit s valve and the main gas valve open the door and windows do not operate electrical switches etc which may cause spark or flame Call our ser...

Page 8: ...LOCATED CONNECTION HOSES MAY NOT BE EXTENDED REPLACED unless by the authorized service 8 15 The device may be carried by man power in hand In case the handling distance is long the device must be moved slowly avoiding rocking balance should be maintained Do not hit or drop the product while handling ...

Page 9: ...hould be operated at balance plane All gas connections must be in compliance with ISO 7 1 or ISO 228 1 standards Prior to the gas connection of the device by the authorized technical service personnel the label must be checked and gas connection must be made according to the specified gas type and pressure Connection according to a different gas type or pressure should not be made 9 15 All of the ...

Page 10: ...EVCE INSTALLATION 10 15 GAS USED G20 NATURAL GAS G30 LPG GAS The rated power of the device absolutely may not be changed according to user demands Any interventions with the valves and injectors to that end will leave the device out of warranty coverage Do not allow any spare parts other than originals to be used on the device In case of application of spare parts not supplied by our company the d...

Page 11: ...GENERAL DIMENSIONS 11 15 ...

Page 12: ...not go out when we release the safety valve we may release it 2 To operate the stove with low flame we have to change the safety valve to low flame position 3 Cooking is made by placing a pot of appropriate size on the cooker 4 An empty fraying pan and or pot should not be placed over the flame 5 Once the cooking process is completed the pan and or pot should be removed from the cooker C TURNING O...

Page 13: ...oth and in contact with the thermo couple d Burner The paths and nozzles for gas flow should always be clean and unclogged e The parts that need to be removed during cleaning and re mounted afterwards have to mounted by technical service personnel and gas leakage must be controlled again by the soap bubble method CLEANING AND MAINTENANCE 13 15 Soften residues of burnt foodstuffs using hot water be...

Page 14: ... PERSONNEL Under such circumstances the device is out of warranty The gas group the device operates on is specified on the label at the location of the gas input WORKING LIFE OF THE DEVICE In case of use under the recommended conditions the working life of the device is 10 years 14 15 SAMPLE LABEL OWG 4070 OWG 4070 OWOG 12090 OWG 4070 OWG 4070 OWOG 12090 OWG 4090 OWG 4090 OWOGD 12090 OWG 4090 OWG ...

Page 15: ... case the consumer uses the repair option but From the date of delivery to the customer with the condition of being within the specified warranty period in addition to the occurrence of the same defect is repeated for more than twice or more than four defects occur within one year or the total number of different defects within the warranty period is over six and the unavailability of the product ...