OZTI OFGI 4070 User Manual Download Page 1

PRODUCTION YEAR: 

SERIAL NO

PRODUCTION SITE

 

: Beylikdüzü Eski Hadımköy Yolu 1.Km Büyükçekmece İstanbul/TÜRKİYE 

                             

Phone : 0090 212 886 78 00 (8 Hat-Lines)   Fax : 0090 212 886 66 29 

Published on

 

 

: 01.01.2013 

VER:V13.01 

1/16 

FRYER (GAS) 

USER’S MANUAL 

Our website:

 

 

www.oztiryakiler.com

                 e-mail: [email protected] 

MANUFACTURER 

 

ÖZTİRYAKİLER MADENİ EŞYA SAN. VE TİC A.Ş. 

 

-

 1783

 

Summary of Contents for OFGI 4070

Page 1: ...B y k ekmece stanbul T RK YE Phone 0090 212 886 78 00 8 Hat Lines Fax 0090 212 886 66 29 Published on 01 01 2013 VER V13 01 1 16 FRYER GAS USER S MANUAL Our website www oztiryakiler com e mail export...

Page 2: ...INTRODUCTION 4 TECHNICAL DATA 5 MAIN DIMENSIONS AND WARNING SIGNS 6 7 SAFETY DETAILS 8 TRANSPORTING AND MOVING 9 10 INSTALLATION OF THE APPLIANCES 11 CONTROL BOARD 12 13 OPERATION OF THE APPLIANCES 14...

Page 3: ...re confused or you don t have enough information please get in touch with authorized service by phone Please keep in mind that if the service personnel is delayed at your site related expenses and del...

Page 4: ...ENSIONS mm 400X900X 850 800 900 850 400x700x850 800x700x850 HEAT POWER KW H QN 22 2x22 44 10 2x10 20 TYPE 1 1 1 1 GAS INLET inch R R R R THERMOSTAT 110 190 110 190 110 190 110 190 SAFETY THERMOSTAT 23...

Page 5: ...MAIN DIMENSIONS AND WARNING SIGNS Figure 1 Main Dimensions and Warning Signs 5 16 HOT SURFACE SAMPLE LABEL MODEL OFGI 4090...

Page 6: ...ts wooden and plastic materials cutting blocks curtains etc should never be held near the appliances You can use this appliances simultaneously together with other products of ours Do not clean up the...

Page 7: ...e power switches and use a fire extinguisher Never use water to extinguish the fire water will cause the fire to spread more faster Oil spilled on the ground during use must be wiped away Otherwise it...

Page 8: ...If the transported distance is far the vehicle should be moved slowly and the appliances should be fixed on palette or supported in order to prevent jolt Do not hit or drop the products when moving C...

Page 9: ...iances should be ensured to operate in a leveled position All of the gas connections of the appliances should complying with ISO 7 1 or ISO 228 1 Gas connections of the appliances should be carried ou...

Page 10: ...STALLATION OF THE APPLIANCES 10 16 Nominal power of the device cannot be changed upon customers request Any modification made on valves and injectors leaves the device out of warranty coverage Do not...

Page 11: ...B D E OFGI 4090 OFGI 8090 700 SERIE OFGI 4070 OFGI 8070 A B F G E A THERMOSTAT ADJUSTMENT VALVE B LIGHTER Piezo Electrical optional C SHUT OFF KNOB D IGNITION BUTTON E LIMIT THERMOSTAT RESET BUTTON F...

Page 12: ...er is ignited You may check the pilot flame by opening the cover After the pilot is lighted thermostat adjustment valve is pressed further maximum 20 seconds to ensure the continuity of the pilot fire...

Page 13: ...he oil drained through the tap underneath the panel and oil container is cleaned A container with suitable size should be used for draining Please be careful during draining the oil inside it may be v...

Page 14: ...quency maintenance period should at most 6 months Expenses of maintenance carried out by our authorized service personnel must be met by the customer even within the guarantee period Please follow the...

Page 15: ...o any gas systems changed by people except for authorized service personnel In this case the appliances will not be covered by the warranty On the label at gas inlet it is specified at which gas syste...

Page 16: ...nd the type of the appliance serial numbers printed on the warranty document are scraped rubbed or changed then the warranty is not valid 6 The warranty covers only maintenance and repairing of materi...

Reviews: