Do not operate with the device  as long as the  enclosure is missing or as long as there 
are errors in its construction.  

The  device  features  an  air  blower  with  an  air  filter.  The  inlet  and  outlet  of  the  device 
must  be  kept  clear  and  may  not  be  blocked  under  any  circumstances.  The  minimum 
distance from walls and objects of the devices should be approx.. 30 cm.  

Do never cover the device or remove it from the applied area during operation. 

The device may not be exposed to a  direct water beam, rain or any  kind of humidity.  If 
water  or  liquids  penetrate  the  device,  it  must  be  switched  off  and  checked  on  by 
professional personnel before operating it again.  

Let the device prior to application acclimate to the surrounding temperature 

This device is only designed for the applications mentioned in this manual. In case the 
device is used for any other application than these, it might lead to hazardous situations. 

Safety measures for indoor-operations 

The  national  relevant  guidelines  for  operation  with  ozone  must  be  followed.  Ozone  is  a  toxic 
oxidizing  agent  and  proves  to  be  hazardous  and  harmful  to  the  health.  There  are  certain  safety 
measures that must be followed to avoid an uncontrolled release of the gas.  

CAUTION:

  Ozone  cannot  be  inhaled!  It  causes  a  reduced  lung  efficiency,  which  can  continue  for 

                  several days! 

Safety measures and equipment:

 

 

Wear masks with ozone filters, which cover the eyes, mouth and nose.  

 

The treated rooms must have a sufficient supply of fresh air and a sufficient air exhaust. 

Seek immediate medical attention in the following cases: 

 

Inflammation of the eye, feeling of dizziness and extensive tussive irritation.  

 

Dyspnoe and pain during inhalation.  

Specified Application 

The  device  is  designed  for  neutralization  of  smells  and  the  disinfection  indoors  by  the  fission  of 
molecules  and  cells  by  means  of  ozone.  The  ozone  is  generated  by  the  device  itself  and  emitted 
through  the  air  blower.  The  device  was  designed  to  neutralize  smells  in industrial  and  commercial 
areas. The operation conditions for this device are an air temperature of +10 to +40 °C and a relative 
air humidity of max. 80 %.  

Standard Delivery Contents:  

1 x ozone generator XT-series 
1 x IR remote control incl. battery 
1 x instruction manual 
 

 

Summary of Contents for XT - series

Page 1: ...2 09 2014 www industrial needs com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southhampton Hampshire United Kingdom SO31 4RF Phone 44 0 2380 98703 0 Fax 44 0 2380 98703 9 info industrial needs com www industrial needs com ...

Page 2: ...rocedure 5 6 1 Turn on device 6 6 2 Start operation 6 6 3 Select operation time 6 6 4 Select performance level of air fan 6 6 5 Shut down operation program 6 7 Initiation 6 7 1 Important notes prior to initiation 6 7 2 Tips on determining the operation period 7 8 Shutdown 7 9 Technical Specifications 8 10 Transportation 8 11 Care and maintenance 8 12 Bug fixing 9 13 Optional Equipment Replacements...

Page 3: ...autions CAUTION The device generates ozone Keep in mind that ozone is toxic and may not be inhaled Please read the following instruction manual before operating with the device Damages caused by disregard of the instructions written in this manual are excluded from any warranty or liability Do not enter the treated room during the device s operation or before the ozone level in the air has adapter...

Page 4: ...ith ozone must be followed Ozone is a toxic oxidizing agent and proves to be hazardous and harmful to the health There are certain safety measures that must be followed to avoid an uncontrolled release of the gas CAUTION Ozone cannot be inhaled It causes a reduced lung efficiency which can continue for several days Safety measures and equipment Wear masks with ozone filters which cover the eyes mo...

Page 5: ... out the ozone containing air back into the surrounding air The ozone in this device is generated without the help of any further chemicals or utilities It only uses electrical energy and surrounding air Thus it causes no environmental pollution After the device is switched off again the remaining ozone dissociates after some time into Oxygen again 5 How to set up the device If you set up the devi...

Page 6: ...modes Fig 1 Layout of control panel on remote control All operation modes can be set by means of the remote control or the control panel on the device as shown below Autom Timer Operation period of the device 15 min 2 hrs Operation indicated by red LED Button to program timer Performance level of air fan level I level II operation indicated by red LED Button to program Air Fan Ozone production Ope...

Page 7: ...an chose the relevant air fan level directly on the remote control 6 5 Shut down operation program All programs can be immediately shut down via the OFF switch red button on remote control After pressing it the device immediately switches into Standby mode and can be programmed again 7 Initiation Check prior to every initiation whether the inlet and outlet for the air fain has no foreign matter in...

Page 8: ...itial non toxic state or reaches the MAK level of 0 1 ppm depends on various factors like the air humidity the treated material size of the room period of treatment etc The treated rooms need to be checked on their ozone concentration by trained and authorized personnel before they become open for access again The mean half life of ozone is 30 min depending on temperature air pressure UV radiation...

Page 9: ...cially the Ceramic Dielectric Electrode requires regular maintenance since it is often covered with contaminants To determine the necessary interval for maintenance consider your operation frequency and the surrounding conditions in which the device is operates If it was a dusty and dirty surrounding or if it is a renovation after fire you should check whether the device requires any maintenance D...

Page 10: ...e sure the electrode is absolutely dry before operating again If you the electrode is much heavier polluted you might have to demount the electrode a Loosen the electrode from its attachment since they are only clipped in b After demounting the plate it can be cleaned carefully under clear water with a mild soap solution e g dishwashing detergent c The device can be remounted after it has fully dr...

Page 11: ...nd an overview of our measuring devices http www industrial needs com measuring instruments htm Here you will find an overview of our scales and balances http www industrial needs com balances htm Here you will find an overview of our laboratory equipment http www industrial needs com laboratory equipment htm Here you will find an overview of our control systems http www industrial needs com contr...

Reviews: