Ozone ContainerMaid CM1000 User Manual Download Page 6

User Manual ContainerMaid ver. 1.4    

 

 Page 6 

 

It is important to choose the correct strength generator, as ozone gas is oxidizing, and overexposure 
of the compactor may result in damaged rubber, hydraulic hoses, electric cables etc. 
If the compactor is empty over some time with ozonation, this may be especially important to take 
into consideration. 

 
Timer:

  

With safety and best results in mind; let ozone concentration reflect odor concentration. 
It is often recommended to run the appliance at intervals via a timer. 
ContainerMaid is available with a built-in Timer (see separate manual enclosed).  
 

WARNING: 

Ensure that the power to the device is disconnected before opening the front cover of the chassis for 
setting of the built-in timer. 
Alternatively, use an external timer connected to the power supply. 
 
The chassis is IP 65, i.e. dustproof and splash proof, but not waterproof. 
The appliance produces corona discharge and must not be installed in environments where there 
may be explosive gas mixtures.  

 

ATTENTION! Ozone Sensor:

  

If ozone is supplied in a closed room where people or animals reside, an ozone sensor should be 
installed. The ozone sensor will shut off the power to the appliance if the ozone level in the room 
exceeds the limit for allowed concentration.  
In Europe 0.1 PPM is the stated occupational exposure limit (upper limit) of the Labour Inspection for 
ozone. (How long people can stay continuously, up to 8 hours, without danger). Contact the 
manufacturer for guidance concerning ozone sensors. 

 

Hydrophobic Membrane Filter:

 

Make sure the filter is mounted on underside of the appliance, in the middle plastic implementation. 
Plastic nut should be loosened and filter pushed into place, about 1.5 cm inward, and nut tightened 
carefully. 

 

Change of Hydrofobic Membran Filter 

 

Summary of Contents for ContainerMaid CM1000

Page 1: ...information regarding the use installation and safety of the product PLEASE READ THE USER MANUAL BEFORE INSTALLING AND OPERATING THE APPLIANCE Contents 1 Explanation of Symbols used in this Manual 2 G...

Page 2: ...d in this Manual The following marks used on the Appliance and in this User Manual refer to the following contents Warning stickers with these marks indicate that correct and safe usage of the Applian...

Page 3: ...ion or lent to a different user please ensure the continuing safe and correct use of the Appliance by placing this user manual where it can be easily found by the next user 3 This device should only b...

Page 4: ...nsible person Be sure to ground the Appliance Do not ground it to a gas pipe water pipe lightning rod or phone cable Imperfect grounding may cause electric shocks Grounding should only be performed by...

Page 5: ...cable and ozone outlet pointing straight down Ozone gas is passed to the odor source through a 6 mm PTFE Teflon hose connected to the outlet stainless fitting of the underside of the appliance The PT...

Page 6: ...ower supply The chassis is IP 65 i e dustproof and splash proof but not waterproof The appliance produces corona discharge and must not be installed in environments where there may be explosive gas mi...

Page 7: ...o Green operating lamp illuminated and a faint buzzing sound emits when ozonation is in process o Red indicator lamp above illuminated indicating high voltage 6 Maintenance Service should only be perf...

Page 8: ...h 2000 mg h Pump capacity 8 l min 8 l min 8 l min 16 l min Timer Opt Opt Opt Opt Outlet for 6 mm PTFE hose Yes Yes Yes Yes Measure LxWxH mm 280x190x90 280x190x90 300x210x100 Weight 3kg 3kg 4kg 5kg Eff...

Reviews: