Permanent Applications
1. Determine the desired location and position for the pump. Refer
“Portable Applications”.
2. Remove the strainer from the
bottom of the pump by depressing
the strainer tabs, on both sides of
the pump.
3. Mount the pump on the strainer so
that both lock tabs snap into place.
(the pump may be reversed on these
tabs if so desired).
4. Attach hose. Refer “Portable Applications”
Wiring
• The submersible pump comes
supplied with an auxiliary
cable. The 12V DC plug on
the auxiliary cable enables
the pump to be powered from
a standard 12V power outlet
found in cars, boats and some
generators.
• The power cord of the
submersible pump also comes
with power cord connectors on
both the pump cord and the
auxiliary cable. This enables
the wires to be connected
quickly and accurately with less
chance of a need for stripping
or cutting.
• The auxiliary cable has a ON/
OFF switch which can be
used to manually control the
submersible pump.
2. WIRING
IMPORTANT!:
ENSURE THAT ALL ELECTRICAL WIRING
IS SECURED IN PLACE WITH THE CONNECTIONS WELL
ABOVE THE POTENTIAL WATER LEVEL.
• If attaching the strainer to
metal or fibreglass, first
mount a wooden block to
the surface, and then fasten
the strainer to the wooden
block.
CAUTION:
THE STRAINER MUST ALWAYS BE
PROPERLY INSTALLED BEFORE ATTACHING AND
RUNNING PUMP.
• If attaching the strainer to
wood, fasten with stainless
steel screws.