Priming the pump is required to purge air from the hose. Don’t
operate the pump without it being primed.
1. Ensure the pump is
switched off at the mains
power.
2. Remove the priming plug
from the top of the pump
housing by turning anti
clockwise.
3. Fill the pump completely
with water. Ensure the
pump and inlet pipe or
hose are full. Replace the priming plug.
4. To fully prime the pump refer to “Starting the pump”.
2. PRIMING THE PUMP
OPERATION
WARNING!:
THIS PRODUCT IS INTENDED
FOR PUMPING WATER IN A HOME DOMESTIC
APPLICATION. DO NOT USE IT FOR CORROSIVE,
ABRASIVE, EXPLOSIVE OR DANGEROUS LIQUIDS.
CAUTION.
THE PUMP SHOULD BE FILLED WITH
WATER AFTER EACH NEW CONNECTION OR IF WATER
LOSS OR AIR INTAKE HAS OCCURRED. EXTENDED
OPERATION WITHOUT A WATER REFILL WILL DAMAGE
THE PUMP!
Connecting to the Discharge Outlet
1. Insert a 1” female threaded
adaptor (not included).
tighten firmly with a
spanner.
2. Securely attach the
output hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe
that is compatible with
your water discharge
application.
Note:
The discharge hose or pipe you are using must have a
minimum diameter of 19mm (3/4’’).
Note:
Ensure the discharge hose or pipe is not restricted in any
way and nothing is obstructing the hose or pipe when the pump
is in operation.
WARNING!:
RISK OF INJURY! IF THE
COMPONENTS ARE NOT COMPRESSION-PROOF
OR IF THEY ARE IMPROPERLY INSTALLED, THE
PRESSURE LINE COULD BURST DURING OPERATION.
Connecting to the Female Socket
1. Connect the pump power
cord plug to the pressure
switch female socket