OPERATION (cont.)
MAINTENANCE
Regulatory Compliance Mark
(RCM)
Warning
V
Volts
A
Amperes
Read Instruction Manual
CCA
Cold Cranking Amps
Wear protective gloves
Wear eye protection
Very hot surface. Do not touch!
Power tools that are no longer usable should not
be disposed of with household waste but in an
environmentally friendly way. Please recycle where
facilities exist. Check with your local council authority for
recycling advice.
Recycling packaging reduces the need for landfill and
raw materials. Reuse of recycled material decreases
pollution in the environment. Please recycle packaging
where facilities exist. Check with your local council
authority for recycling advice.
CARING FOR THE ENVIRONMENT
SPARE PARTS
Spare parts can be ordered from the Special Orders Desk at your
local Bunnings Warehouse.
For further information, visit www.ozito.com.au or contact Ozito
Customer Service:
Australia 1800 069 486
New Zealand 0508 069 486
E-mail: [email protected]
DESCRIPTION OF SYMBOLS
•If the enclosure of the battery load tester requires cleaning, do not use
solvents. Use a moist, soft cloth only. Never immerse any part of the
Battery load tester into liquid.
• Keep terminal clamps clean and dry at all times.
BATTERY ANALYSIS
LOAD TEST
BATTERY CONDITION
Good (Green)
Battery capacity is OK. Battery may or may not be fully charged. Check specific gravity of
battery to determine state of charge, check the electrical drain or possible charging system
trouble.
Weak or Bad, but
the Needle remains
steady
(Yellow or Red)
Battery capacity is not satisfactory. Battery may be either defective or not fully charged. Check
specific gravity to determine which condition exists. If charging does not bring specific gravity
to full charge level, battery should be replaced.
Weak or Bad,
but the Needle
continues to fall
(Yellow or Red)
Battery may be either defective or very run down. Release the Load Test Switch and note
volt meter reaction. Voltage recovery to 12 volt or above within seconds indicates a defective
battery. Slow voltage recovery indicates run down condition. For best results, check specific
gravity.