Fitting The Air Filter

1.  Remove the transportation cover from the air filter connection with 

a screwdriver.

2.  Attach the supplied air filter by 

screwing it in clockwise.

Fitting The Oil Sealing Plug

1.  Remove the transportation cover from the oil filler opening with a 

flathead screwdriver.

2.  Insert the oil sealing plug into 

the oil filler opening.

Checking The Oil Level

1.  Place the compressor on a level surface.

2.  Check that the oil level is 

between the the ‘MAX’ and 

‘MIN’ marks on the oil level 

window.

3.  If the oil level is below the ‘MIN’ mark, refer to the Maintenance 

section - Changing The Oil and follow the directions for refilling the 

oil in the compressor.

Switching The Compressor On/Off

1.  To switch the compressor on, 

press the on/off switch to the 

‘I’ position. Allow the motor to 

run and the tank to fill up.

Note:

 

The compressor will automatically cut off when the tank 

pressure reaches 8bar and will automatically start up again when the 

tank pressure drops to 5.5bar.

2.  To switch the compressor off, press the on/off switch to the ‘0’ 

position.

Restarting The Compressor If It Overloads & Shuts Off

The motor is fitted with an overload switch which turns off the 

equipment automatically to protect the compressor from overheating. 

1.  If the overload switch triggers, switch off the compressor using the 

On/Off Switch and wait until the compressor cools down.

2.  Press the Overload Reset 

Switch and restart the 

compressor.

WARNING! 

DO NOT CONTINUE USE OF THE 

UNIT IF THE OVERLOAD SWITCH TRIPS AGAIN 

IMMEDIATELY AFTER THE RESET.

2. CONTROLS

OPERATION

Max.

Min.

0

50

100

150

200

225

ON

OFF

WARNING! 

THE AIR COMPRESSOR MUST BE USED 

WITH A RESIDUAL CURRENT DEVICE WITH A 

RATED RESIDUAL CURRENT OF 30MA OR LESS.

WARNING! 

DO NOT LEAVE THE AIR COMPRESSOR 

UNATTENDED WHILE THE ON/OFF SWITCH IS IN 

THE ‘ON’ POSITION.

Summary of Contents for ACP-2420

Page 1: ...nts or alterations Failure to perform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANT...

Page 2: ...L IN THE MOTOR TO LEAK OUT AND DAMAGE THE UNIT Attaching The Support Foot 1 Insert the support foot bolt through the hole in the frame for the support foot and secure it in place with a Nyloc nut Atta...

Page 3: ...ank to fill up Note The compressor will automatically cut off when the tank pressure reaches 8bar and will automatically start up again when the tank pressure drops to 5 5bar 2 To switch the compresso...

Page 4: ...BE DISCHARGED AT HIGH PRESSURE DO NOT USE THE COMPRESSOR IF THE SAFETY VALVE DOES NOT WORK AS DESCRIBED The safety relief valve has been set for the highest permitted pressure of the tank It is prohib...

Page 5: ...not start Compressor has reached cut out pressure Compressor will automatically start once below the cut in pressure No power supply Check the power supply the power plug and the socket outlet Insuff...

Page 6: ...ls from the compressor before cleaning Do not clean the compressor with water solvents or the like Draining The Pressure Tank WARNING RELEASE ALL AIR PRESSURE FROM THE TANK BEFORE OPENING THE DRAIN VA...

Page 7: ...h is not accessible to unauthorised persons Supply Cords If the replacement of the supply cord is necessary this has to be done by a certified electrician in order to avoid a safety hazard Note Ozito...

Page 8: ...line but immediately keep bystanders well clear and turn off the air supply to the hose turn off the compressor at the On Off button and then remove the hose from the compressor AIR COMPRESSOR SAFETY...

Reviews: