OZCO OWT 301 Manual Download Page 5

V2.00 - Installation Instructions, Specifications and Project Plans are effective 4/28/2016 . This information is updated periodically 
and should not be relied upon after 2 years from 4/28/2016 . Please visit OZCOBP.com to get current information.

ITEM 

NO. QTY.

PART 

NUMBER

DESCRIPTION

1

4

6x6 Cedar 

Post

6x6x96.00

2

4

2x10 

Cedar 

Board

2x12x144.00

3

12 2x6 Cedar 

Board

2x6x144.00

4

2

2x10 

Cedar 

Board

2x10x192.00

5

4

6x6 Cedar 

Support

6x6x36.00

6

4

6x6 Cedar 

Support

6x6x48.00

7

3.2

51717

2" Standard 

Rafter Clip (RC-

IW-2)

8

4

51737

Bolt Inline (P2B-

BI-IW)

9

4

51708

6x6 Post Base 

(6x6-PB-IW)

10

0.96

56628

Screw, OWT 5-

3/4" (145mm) 

Timber with 

HCN

0.1

  56621

1 1/2" Hex Cap 

Nut (HCN)

11

4

56652

OWT Timber 

Bolt 10-12"

12

0.64

56625

Screw, OWT 1-

3/4" (45mm) 

Timber with 

HCN

0.1

  56621

1 1/2" Hex Cap 

Nut (HCN)

Bill of Material

OZCO Project #301 - Deck Pergola with 6x6 
Posts

5

7

3

12

4

5

6

10

11

8

9

1

2

Summary of Contents for OWT 301

Page 1: ...This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information post base shown with optional 2 3 8 Star 56623 OZ...

Page 2: ...tive 4 28 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information Overview Front OZCO Project 301 De...

Page 3: ...ctive 4 28 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information 370 14 56 typ Overview Top OZCO P...

Page 4: ...ns are effective 4 28 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information Overview Right OZCO Pr...

Page 5: ...4 00 3 12 2x6 Cedar Board 2x6x144 00 4 2 2x10 Cedar Board 2x10x192 00 5 4 6x6 Cedar Support 6x6x36 00 6 4 6x6 Cedar Support 6x6x48 00 7 3 2 51717 2 Standard Rafter Clip RC IW 2 8 4 51737 Bolt Inline P...

Page 6: ...s are effective 4 28 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information Suggested Tools others...

Page 7: ...tive 4 28 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information OZCO 7 OZCO Project 301 Deck Pergo...

Page 8: ...dically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information Laredo Sunset Ironwood Laredo Sunset Ironwood 8 2 great styles Same functionality...

Page 9: ...om 4 28 2016 Please visit OZCOBP com to get current information Cutlist 9 OZCO Project 301 Deck Pergola with 6x6 Posts 6x6 Cedar Support 4 45 1219 48 00 2x6 Cedar Board 12 with Chamfer 2 ends 51 2 00...

Page 10: ...ated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information 4067 160 13 4965 195 48 2848 112 13 Site Plan 10 OZCO Project 301 Deck P...

Page 11: ...28 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information step 1 11 OZCO Project 301 Deck Pergola...

Page 12: ...on is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information step 2 12 OZCO Project 301 Deck Pergola with 6x6 Posts Tool Req...

Page 13: ...8 2016 This information is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information step 3 13 OZCO Project 301 Deck Pergola wi...

Page 14: ...ated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information step 4 14 OZCO Project 301 Deck Pergola with 6x6 Posts install in decora...

Page 15: ...n is updated periodically and should not be relied upon after 2 years from 4 28 2016 Please visit OZCOBP com to get current information step 5 15 OZCO Project 301 Deck Pergola with 6x6 Posts see Overv...

Reviews: