12.
Battery Management System (BMS)
Thanks to years of research and development your
OzCharge
®
Lithium battery has state of the art
technology monitoring the battery. Internally within your battery, an active Battery Management System
or BMS constantly monitors the individual cells for voltage, temperature, state of charge, cell balance,
discharge loads, charge voltage and charge current.
BMS Protections:
Event
Model
Protection Condition
Reset Condition
Over Discharge
OCBL12-44 & OCBL12-55
<10V / 50—300mS
>10V / Cut Load
,Auto release
OCBL12-80, OCBL12-100,
OCBL12-120, OCBL12-200 &
OCBLS12-160
<10V / 3.7-5.7S
>10.6V / Cut Load
,Auto release
OCBL36-100
<30V / 10-300ms
>31.2V / Cut Load
,Auto release
Over Charge
OCBL12-44 & OCBL12-55Ah
>14.8V / 0.5-2S
<14.4V
OCBL12-80, OCBL12-100,
OCBL12-120, OCBL12-200 &
OCBLS12-160
>14.88V / 0.5-1.5S
<14.4V
OCBL36-100
>44.4V / 0.8-2S
<42V / 5S
Over Discharge
Current
All Models
Please Refer to Product Label and / or
Specific Data Sheet
Short Circuit Current
All Models
Please Refer to Product Label and / or
Specific Data Sheet
High Discharge
Temperature Protect
All Models
65°C±
45°C±
High Charge
Temperature Protection
All Models
65°C±
48°C±
Active Cell Balance
OCBL12-44, OCBL12-55,
OCBL12-80,OCBL12-100,
OCBL12-120, OCBL12-200 &
OCBSL12-160
>14V
Automatic as required
OCBL36-100
>42V
Automatic as required
13.
General Specifications
Nominal Voltage
12.8V, 24V, 36V or 48V (model dependant)*
IP Rating
IP65 or IP67 (model dependant)*
Parallel Connection
4 Max**
Series Connection
4 Max** (12.8V Models only)
0 for 24V, 36V and 48V models
Case Material
Flame Retardant ABS Plastic
Battery Terminal Torque Setting
M6 (4-6 Nm Torque)
M8 (7-9 Nm Torque)
Operating Temperature Range
-20
o
C~+60
o
C Relative Humidity
≤
85%
Charge Temperature Range
0
o
C – 55
o
C
Charge Voltage 12.8V (for OCBL12-XXX)
14.4V ± 0.2V @ 0°C to 55°C
Charge Voltage 24V (for OCBL24-XXX)
28.8V ± 0.4V @ 0°C to 55°C