![Oxygen PERSEUS 230V Installation Manual Download Page 4](http://html1.mh-extra.com/html/oxygen/perseus-230v/perseus-230v_installation-manual_1665237004.webp)
INSTALLATION
A = 105mm = VERTICAL DISTANCE BETWEEN THE TEETH OF THE RACK AND THE GROUND
B = 20mm= HORIZONTAL DISTANCE BETWEEN THE DRIVE WHEEL AND THE GATE
C = 55mm = HORIZONTAL DISTANCE BETWEEN THE BASE OF THE MOTOR AND THE GATE
FOUNDATION PLATE (OPTIONAL)
If the base has yet to be prepared and the installation of the motor is not
immediate, it is possible to cement the foundation plate (NOT INCLUDED)
following the installation dimensions Par. 1 / FIG.1
– Position the foundation plate as shown in FIG. 3 using the log bolts
supplied with the plate
INSTALLING THE RACK
If the rack is already installed, check that there is a space of approximately
1mm between the drive wheel and the rack FIG. 4,
if the rack is not installed, proceed as follows:
– Take the first piece of rack and position it on the motor sprocket making
sure that at the end of the installation there is always 1mm of space (if
necessary use temporary shims under the motor). Slide it to the point
indicated in FIG. 4
– Weld or screw the first pin or spacer to the gate (depending on the type
of rack).
– Apply all the other elements of the rack so that they are perfectly joined
and aligned with the first one. Use pliers and a piece of rack for perfect
alignment of one element with the other. See FIG. 5
A
B
FIG. 3
FIG. 4
FIG. 5
C
325mm
288mm
72mm
155mm
125mm
FIG. 1
Summary of Contents for PERSEUS 230V