TECHNICAL DATA 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

12V 

24V 

220V 

MAX. door length 

2,0m 

2,0m 

3,0m 

MAX. gate weight 

200Kg 

200Kg 

300Kg 

Power supply 

12Vdc 

24Vdc 

220V 

Power 

70W 

70W 

350W 

Capacitor 

8,0µF 

Absorption 

1,4 

– 8,3A 

1,4 

– 5,3A 

1,1A 

RPM 

1500 

1500 

1400 

Maximum thrust 

260N 

260N 

320N 

Working temperature 

-25°C +60°C  -25°C +60°C  -25°C +60°C 

Thermal protection 

– 

– 

150°C 

Frequency of use 

80% 

80% 

15% 

Lubrication 

Grasso 

Grasso 

Grasso 

Fixing plate dimensions 

380x180x155  380x180x155  380x180x155 

Summary of Contents for ARACHNE

Page 1: ...installation the installer must carry out a risk analysis of the final automated closing and safety of the entire system following EN 12453 and EN 12445 standards The wiring of the various electrical...

Page 2: ...ation of the ecological platforms suitable to receive the product for disposal and its subsequent proper recycling Please also note that in exchange for the purchase of an equivalent appliance the dis...

Page 3: ...ged or cannot be removed take care of the following to their replacement been applied EN292 1 2 EN 294 EN60335 1 UNI EN 12453 as far as EN12445 2000 is applicable USE OF AUTOMATION The ARACHNE geared...

Page 4: ...ate weight 200Kg 200Kg 300Kg Power supply 12Vdc 24Vdc 220V Power 70W 70W 350W Capacitor 8 0 F Absorption 1 4 8 3A 1 4 5 3A 1 1A RPM 1500 1500 1400 Maximum thrust 260N 260N 320N Working temperature 25...

Page 5: ...gearmotor A B Alfa A B Alfa A B Alfa A B Alfa 0 cm 16 20cm 90 5 cm 25 35cm 110 15 cm 16 20cm 90 20 cm 16 35cm 90 0 cm 20 35cm 120 10 cm 16 20cm 90 15 cm 20 25cm 100 25 cm 16 30cm 90 5 cm 16 20cm 90 10...

Page 6: ...king it with the supplied A key until you hear the first click Fig 5 7 Using the articulated arm position bracket A on the gate so that the angle of the two elements of the articulated arm does not ex...

Page 7: ...ed 8 Make a complete movement of the sash by checking the correct arm movement 9 Check the fixings and proceed with the electrical connections adjust the A B cams of the limit switches as indicated in...

Page 8: ...que adjustment of the control unit Semiannual Electrician Check the torque setting as indicated in EN 12453 EN 12445 Protection degree control Semiannual Electrician Check that there are no traces of...

Reviews: