Installation guidelines
21
D4 indicates a signal to the «LEFT» input.
D5 indicates a signal to the «RIGHT» input.
D6 indicates signal to the «STOP» input.
D7 signals a signal to the «AP» input.
Jumper J4 shall be installed. It is used to connect a 120 Ohm resistor to
CAN
2.0
bus
to
ensure
its
normal
operation.
If using two remote controls J4 shall not be installed, because 120 Ohm
resistors are installed on CL and CH contacts in remote control panels.
5.4. Connecting RC panel to ACS controller
In some cases RC shall be connected directly to the ACS controller
as the passages allowed from the remote (without controller) are regarded
by the system as a "forced entry".
To use this connection pattern of turnstile J2 jumper shall be set on
the motherboards (Fig. 8). When J2 jumper is set the turnstile does not
respond to remote control panel commands but only transmits their status
to contacts of I / O1 ... I / O4 terminal boards (Fig. 8) which are open
collector outputs. Contacts assignment is shown in Table 6. The
numbering of the remote control buttons is shown in Fig. 9. The maximum
output current for this set of contacts is 150 mA, maximum voltage rating
is 24 W.