background image

 

Praktika K-01 card collector 

 10 

7. Operation of card collector 

 

7.1. Startup 

 
Connect the power supply unit to network 220V and turn it on. Card 

collector  will  beep  and  red  cross  will  turn  on  LED  panel  (Fig.  1).  Card 

collector is ready for operation. 

 

7.2. Working modes 

 

Standby mode 

The mode is set after power-up. In this mode, the card collector waits 

for  a  signal  from  ACS  controller.  Red  cross  is  turned  on  on  the  display. 

The mode of minimal power consumption. 

 

Passage with permanent cards  

When an authorized permanent visitor card is presented to the reader 

card  collector  unlocks  the  speedgate  for  the  time  specified  by  ACS 

controller  (depending  on  the  operating  mode;  for  5  seconds  in  pulse 

mode).  During  the  specified  time  interval  other  cards  are  not  accepted. 

When  the  passage  is  performed  or  the  specified  time  interval  is  expired 

card  collector  switches  into  standby  mode  and  can  collect  the  next  card. 

Green arrow turns on on the LED panel, indicating the authorization of the 

passage. 

 

 

Summary of Contents for Praktika K-01

Page 1: ...Operational manual www oxgard com info oxgard com Tel 7 812 366 15 94 Praktika K 01 card collector...

Page 2: ......

Page 3: ...rpose 5 2 Delivery set 5 3 Basic specifications 6 4 Product design 7 6 Safety requirements 9 7 Operation of card collector 10 7 1 Startup 10 7 2 Working modes 10 7 3 Removing guest cards from card rea...

Page 4: ...Praktika K 01 card collector 4 List of abbreviations PS power supply ACS access control system OD operating device Firmware version FW v1 52...

Page 5: ...tegrated with any type of access control system 2 Delivery set Table 1 Delivery set Item Qty pcs Praktika K 01 card collector 1 Hatch key lock 2 Datasheet 1 Operational manual 1 Installation guideline...

Page 6: ...peration transportation and storage 1 40 1 40 Atmosphere relative humidity no more than 80 Supply voltage V nominal working 12 8 18 Average current in standby mode A 0 2 Maximal current A 1 5 Maximal...

Page 7: ...here is a hatch with lock for quick access to collected cards and to the board where PS OD and ACS cables are connected The hatch includes a card storage device The lower part of housing is equipped w...

Page 8: ...limitation It is allowed to stack boxes in 3 rows during transportation and storage if Euro pallets used Keep the card collector in dry no moisture condensation heated places within 1 to 40 C tempera...

Page 9: ...ims any liability for damage to human life and health total or partial loss of workability of products and or auxiliary equipment for non compliance of the safety requirements specified in this sectio...

Page 10: ...urned on on the display The mode of minimal power consumption Passage with permanent cards When an authorized permanent visitor card is presented to the reader card collector unlocks the speedgate for...

Page 11: ...single blinks 1 time in 2 sec Passages with permanent cards are performed normally In order to switch the card collector in the standard operating mode remove cards from the storage device see Articl...

Page 12: ...plied underneath storage device 7 3 3 Gently lift the storage curtains to remove the cards 7 3 4 Lower the storage curtains and close the door with a key 7 4 Inversion of LED panel board In some cases...

Page 13: ...Operational manual 13...

Page 14: ...Praktika K 01 card collector 14 Appendix 1 Typical faults Fig 3 Location of optocouplers of card collector...

Page 15: ...ensor optocoupler is broken Fig 3 Check the condition of the cables and connectors If D9 LED on the board of the card collector does not turn red the fault is caused by the malfunction of motherboard...

Page 16: ...nnectors while holding down the button BUT1 1 IR LED1 Vtyp 1 2 B If V 5 V LED or cable defective 2 Card1_ph Vtyp 0 1 B Vmax 2 5 V If V 2 5 In all right If V 2 5 V disaligment or LED and phototransisto...

Page 17: ...If V 5 V phototransistor or cable are defective...