VZR.247800.001
IM
Turnstile CUBE C-03
Installation Manual
26
5.4 Connecting the control panel to the ACS controller
In some cases, the turnstile CP should be connected directly to the ACS
controller, since the system responds to passing allowed from the control panel
(without using the controller) as on "hacking".
To use this diagram for connecting the turnstile, it is necessary to set the
control board to mode number 6 using the BUT button (see Table 1). The turnstile
does not respond to the control panel commands during this setting process and
only transmits their status to the contacts of the ACCES_OUT control board
terminal blocks. Figure 10
– (LEFT, RIGHT, STOP, AP) which are outputs with an
open collector.
The contact assignment is shown in Table 4, Figure 12
–numbering of the
control panel buttons. For this group of contacts, the maximum output current is
not more than 150 mA and permissible voltage is not more than 12 V.
Figure 12
– Numbering of the CP buttons
1, 2, 3, 4 - control buttons
1, 2, 3, 4 - control buttons