Page 1: ...PCT504 ZigBee Fan coil Thermostat Quick Start Guide ...

Page 2: ...d all the safety notices below before using the Fan coil Thermostat Avoid high humidity or extreme temperatures Avoid long exposure to direct sunlight or strong ultraviolet light Do not drop or expose the unit to intense vibration Do not disassemble or try to repair the unit on your own Do not expose the unit or its accessories to flammable liquids gases or other explosives ...

Page 3: ...ion Warning Risk of electrical shock The thermostat must be installed and serviced only by a qualified electrical personnel Read these instructions carefully Do not touch the terminals of the device during testing Turn off all the power supply for this equipment before installing Make sure that the power supply is off before connecting or disconnecting it to an auxiliary device Always use a proper...

Page 4: ...pply wires through the backplate Then attach the backplate to the junction box using the screws Location The thermostat has a built in sensor to detect room temperature and humidity for a better sensing result it must be located about 1 5m 5ft above the floor The ideal location is where the thermostat is accessible have a good air circulation reasonably lit and free from extremes of temperature an...

Page 5: ...5 OPEN 4 Attach the supply wires Attach the supply wires directly to the terminals on the rear of the thermostat ...

Page 6: ... off 5 Attach the thermostat to the backplate Gently push the thermostat to the backplate until it locks 6 Power on your system Congratulation you are now finished with the installation Please power on your HVAC system 7 Setup the thermostat Power on your thermostat Set your gateway to permit joining and the thermostat will join into the gateway automatically the X sign of the network indicator on...

Page 7: ...7 Wiring Diagrams Yon Yoff N GL GM L GH Won Woff HEAT VALVE FAN N L Two pipes Heat only ...

Page 8: ...8 Yon Yoff N GL GM L GH Won Woff HEAT VALVE FAN COOL VALVE N L Yon Yoff N GL GM L GH Won Woff FAN COOL VALVE N L Two pipes Cool only Four pipes Heat and Cool ...

Page 9: ...to switch between Fan modes High Medium Low Auto Up Down button Adjust temperature Press to increase Decrease the setpoint temperature Lock Unlock Press an hold the up button and down button together for 3s until a lock icon appears disappears on the screen to lock unlock the device PIR Screen will automatically light up when someone is approaching ...

Page 10: ...ch Sleep Mode Button Sleep mode Press to enter sleep mode Schedule Press and hold the sleep mode button for 3s until a schedule icon appears disappears on the screen to enable disable the schedule Eco Mode Switch Press to enter eco mode ...

Page 11: ...ature setpoint Network indicator Heating Mode Cooling Mode Ventilating Mode Sleep Mode Eco Mode Setting Schedule Lock Setting To enter the setting menu please press the on off button to turn off the thermostat then press and hold the Mode button for three seconds until the screen lights up Use the Mode button to switch from different setting options and Up Down button to change settings ...

Page 12: ...status after a power cycle 2 Remain off status unless turned on Default setting 1 P2 Temperature calibartion Range 4 C 4 C 39 F 39 F Default setting 0 P3 Heating setpoint temperature for Eco mode Range 5 C 18 C 41 F 64 F Default setting 15 C 59 F ...

Page 13: ...5 F Default setting 30 C 86 F P5 Fan setting ON Associate the fan with the output of the water valve the fan stops when the valve stop OFF Fan works independently Default setting OFF P6 Temperature unit setting Switch between Fahrenheit and Celsius Default setting Celsius ...

Page 14: ...tting 24 hour time P8 PIR setting ON Screen will automatically light up when someone is approaching OFF Disable PIR sensor Default setting ON P9 Sound setting ON Enbale sound feedback when a button is pressed OFF Disable soundfeedback when a button is pressed Default setting ON ...

Page 15: ...P11 P13 Schedule setting off You can set schedules for a whole week to turn off the device at a desired time on these two pages Default setting N A Note To enable disable schedules press and hold Sleep button on the main interface for three seconds until the schedule icon appears disappears P14 Firmware version C h e c k t h e f i r m wa re version ...

Page 16: ...onds until the screen lights up 3 The thermostat will go back to main interface once the reset is completed 2 How can I tell if the thermostat successfully joins a ZigBee network A2 You can refer to the Network indicator on the upper right of the screen If the thermostat has not joined a network there will be a X icon on the network indicator Once the thermostat joined a network the X icon will di...

Page 17: ...e Smart Energy Profile Data Interfaces UART Micro USB port Power Supply AC 110 250V 50 60Hz Rated power consumption 1 4W LCD Screen 2 4 LCD 128 x 64 pixels Operating temperature 0 C to 40 C Dimensions 86 L x 86 W x 48 H mm Weight 198 g Thermostat 4 pipes Heat Cool Fan coil system System mode Heat Off Cool Ventilation Fan mode AUTO Low Medium High Power method Hardwired Sensor element Humidity Temp...