background image

STEP 5

Compare the reading on the WaveTester to Table 1 for acceptable power levels.   The patch cable 

should be replaced if it is below the acceptable power level.

STEP 6

Once proper operation has been verified, remove the first patch cable from both units and set it aside.

STEP 7

Connect the power meter and light source together with the second patch cable as shown in Figure 3. 

STEP 8

Compare the reading on the WaveTester to Table 1 for acceptable power levels.     The patch cable 

should be replaced if it is below the acceptable power level.

STEP 9

Once proper operation has been verified, remove the second patch cable from both units and set it 

aside.

STEP 10

Connect the power meter and light source together with the mandrel-wrapped patch cable as shown in 

Figure 4 below. 

STEP 11

Compare the reading on the WaveTester to Table 1 for acceptable power levels.

   

 The patch cable 

should be replaced if it is below the acceptable power level.

STEP 12

Once proper operation has been verified, continue on to the next step.

SET REFERENCE 

STEP 13

Press and hold the UNITS/ZERO button on the WaveTester to set the reference for 850nm.

The WaveTester display should change to show readings in ‘

dB

’, and the power reading should be approximately 0.00 

dB.  This means that the meter and light source have been successfully “zeroed” at 850nm.

NOTE:

 if you are also testing at 1300nm, you will need to connect 

a separate  mandrel-wrapped patch cable

 

to the 1300nm port.

STEP 14

Connect the 1300nm mandrel-wrapped patch cable to the detector port on the WaveTester.

STEP 15

Press  

8

/AUTO

 several times until the WaveTester is set to 1300nm.

STEP 16

Press and hold the 

UNITS/ZERO

 button on the WaveTester to set the reference for 1300nm.

The WaveTester display should show a power reading of approximately 0.00 dB.  This means that the meter and light 
source have been successfully “zeroed” at 1300nm.

Core Size

62.5/125 µM

50/125 µM

Replace at

-22.00 dBm
-25.00 dBm

Acceptable Power Level

-19.0 to -22.0 dBm
-22.0 to -25.0 dBm

TABLE 1

FIGURE 4

Set

Optical

Reference

dBm

20.00

-

850

nm

 LIGHT SOURCE CONNECTOR 

PORT NOTES:

– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED 

PHYSICAL CONTACT (APC) 
CONNECTOR

Summary of Contents for KIT-WT-D2stKIT-WT-D2sc

Page 1: ...one 262 473 0643 Internet OWL INC COM Revision 1 1 26009 WaveTester Series Test Kits Certification Testing Quick Reference Guide For part numbers KIT WT D2st KIT WT D2sc e C s i h o W i c e e h i T n O s p e i t r i c o a t l a r F o i b b e a r L T h e t s g t n E e l q e u v i p a m W e l n a t c i t p O OWL Optical Wavelength Laboratories ...

Page 2: ... or fail by Complete understanding of each of these issues is critical for performing proper fiber optic tests GETTING STARTED Thank you for your purchase of this OWL certification test kit Included in this kit is a WaveTester optical power meter and a WaveSource multimode fiber optic light source This quick reference guide will assist you in setting up your test kit for a standards based certific...

Page 3: ...e EQUIPMENT PORTS Figure 2 shows the ports used during this procedure These ports may vary depending upon the model of equipment VERIFY PROPER OPERATION OF THE EQUIPMENT STEP 1 Connect the power meter and light source together with the first patch cable as shown in Figure 3 STEP 2 Power on the light source STEP 3 Power on the WaveTester STEP 4 Press 8 AUTO several times until the wavelength is set...

Page 4: ... verified continue on to the next step SET REFERENCE STEP 13 Press and hold the UNITS ZERO button on the WaveTester to set the reference for 850nm The WaveTester display should change to show readings in dB and the power reading should be approximately 0 00 dB This means that the meter and light source have been successfully zeroed at 850nm NOTE if you are also testing at 1300nm you will need to c...

Page 5: ...t until all fibers have been tested at 850nm STEP 23 For testing 1300nm again connect to the first fiber under test except this time use the mandrel wrapped patch cable connected to the 1300nm port STEP 24 Press 8 AUTO several times until the WaveTester is set to 1300nm STEP 25 Press SAVE on the WaveTester to store the reading for the current fiber under test STEP 26 Disconnect the patch cables fr...

Reviews: