DELFIN MEGA
37
Operation
hardness can occur.
b)
Press both locking hooks inwards (
16
)
on the control head side and remove the
cover (
2
).
c)
Enter the date of installation on the label
(
18
) provided for this purpose.
Changing of the preset hardness range:
The hardness range of the mains water
must be set at the electronic control using
the DIP switch (
26
). Open the contact as-
signed to the hardness range (push into the
position opposite to “ON” (see fig. 5)).
Only one of the contacts may be opened.
The circuit responds to an incorrect setting
by emitting an audible signal. Contacts 4 to
8 are closed (position “ON”).
Fine adjustment
is undertaken with the
supplied hex key by rotating the
adjusting
screw
(
17
).
Hardness range A: Double the value of the
measured raw water hardness must be set.
Hardness range B: The value of the meas-
ured raw water hardness must be set (½
turn = 1 °dH).
Hardness range C: Half the value of the
measured raw water hardness must be set.
d)
Open the water supply (stopcock or
shut-off valve) and/or set the bypass
valve to the “Operation” position.
ATTENTION
For safety reasons, the softener must be
vented immediately after connection to the
water mains.
This occurs either automatically upon first re-
generation (see
) or can be performed man-
ually as follows:
The axle (
23
) of the drive wheel is rotated
clockwise
using a 13 mm open-ended
spanner. The waste water hose (
3
) must be
securely attached to prevent a “pressure-
flutter”. In the area of the two salting posi-
tions and four flushing positions (markings
2, 3, 5, 7, 8, 10 on the operating phase dis-
play (
24
)) the rotational movement must be
stopped for about 30 seconds each. At the
Hardness range
DIP
switches
A 6-11
°dH
medium hard
Contact 1
B 12-24 °dH
hard to
very hard
Contact 2
C 25-48 °dH
very hard
Contact 3
Tab. 1: Hardness range
Fig. 5 : DIP switch
Hardness
range
Raw water-
hardness
Value
to be set (17)
A
6 °dH
12 °dH
7 °dH
14 °dH
8 °dH
16 °dH
9 °dH
18 °dH
10 °dH
20 °dH
11 °dH
22 °dH
B
12 °dH
12 °dH
13 °dH
13 °dH
•
•
•
•
•
•
23 °dH
23 °dH
24 °dH
24 °dH
C
26 °dH
13 °dH
28 °dH
14 °dH
•
•
•
•
44 °dH
22 °dH
46 °dH
23 °dH
48 °dH
24 °dH
Tab. 2: Raw water hardness
Summary of Contents for DELFIN MEGA
Page 3: ...DELFIN MEGA 3...
Page 20: ...20 DELFIN MEGA Ersatzteile 11 Ersatzteile...
Page 21: ...DELFIN MEGA 21 Ersatzteile...
Page 22: ...22 DELFIN MEGA Ersatzteile...
Page 23: ...DELFIN MEGA 23 Ersatzteile...
Page 29: ...DELFIN MEGA 29...
Page 46: ...46 DELFIN MEGA Spare parts 11 Spare parts...
Page 47: ...DELFIN MEGA 47 Spare parts...
Page 48: ...48 DELFIN MEGA Spare parts...
Page 49: ...DELFIN MEGA 49 Spare parts...
Page 55: ...DELFIN MEGA 55 Notizen Notes...