background image

PROBLEM

POSSIBLE CAUSE

SOLUTION

NOTES

Propane tank was not purged properly

Return the tank to an authorized propane station 
and re-purge the propane tank.

The Purge process requires that all air is removed 
from the propane tank prior to the first fill

The OPD float valve on the propane tank has 
been activated, closing the  valve and not 
allowing the tank to fill.

Attach the regulator to the propane tank, turn the 
control valve on for a few seconds to reset the 
OPD float valve.

The OPD float valve is a safety device which is 
activated when the propane tank has been filled 
too quickly.

Control valve not closed completely.

To shut off the valve, push the control valve in 
slightly to unlock and turn to the right (Clockwise) 
completely.

The far right position on the control valve is the 
off position

The regulator was not properly secured to the 
propane tank.

Disconnect the regulator and reconnect it properly 
to the propane tank.

The Regulator needs to be tightened securely & 
fully to the Propane Bottle to prevent propane 
leaks & to supply the correct amount of propane.

The tank was not purged properly, it contains a 
mixture of air and propane.  The results is 
intermittent flame, or flame extinguishes in a short 
period of time.

Burn off the remaining propane and re-purge the 
tank.

The purging process requires that ALL the air is 
removed from the propane tank during the first fill 
to ensure maximum efficiency.  See your local 
authorized propane dealer.

In cooler temperatures, the liquid propane does 
not convert quickly enough to gas therefore 
causing the tank to freeze on the outside.

Turn the control valve to the low position where 
the flow is not as high.

Flame setting too low.

To Increase the flame, Turn the control valve 
clockwise to the 12 o'clock position to get the 
maximum amount of BTU's.

Flame setting too high.

To lower the flame, Turn the control valve counter 
clockwise from the 12 o'clock position a quarter 
turn to the set low position and a lower amount of 
BTU's.

Spiders may have created webs or insects may 
have created nests inside the venturi or orifice.

Make sure the fire pit is not is use & has not been 
used  recently and the unit is cold to the touch so 
as to not get burned.  Make sure the control valve 
is in the off position.  Close the propane tank valve 
or the fix piping supply line valve.  See page 12 of 
this manual on Converting Your Fire Pit to a 
Different Gas Type on how to access the venturi & 
the orifice.  Insert a small wire in the venturi & 
orifice holes to clear passage free of spider webs 
or other debris.  Make sure to put everything back 
correctly when finished for proper fire pit operation 
and safety.

This is a common problem when the fire pit has 
not been used for an extended period of time.

Low or Excessive Flame

Using Natural Gas

The water column may not have been adjusted 
correctly.

Contact your local licensed plumber or certified 
tech for assistance.

Fire Pit Wobbles

Cement slab or the use of natural stone may not 
be completely even.

Optional adjustable fire pit glides are available 
through your local dealer.

Optional glides are perfect for areas where the 
draining slope to level out a fire pit.

TROUBLE SHOOTING GUIDE

Propane Tank Does Not Fill

You Smell Propane or 

a Rotten Egg Smell

Immediately Stop!

See Warnings &

 

Instructions

 on Page 1

Flame Problems:

No Flame

Intermittent Flame

Low Flame

ADDITIONAL CARE AND INSTRUCTIONS

DO NOT

 remove the glass wind guards until it has completely cooled, approximately 1/2 hour.  Check to be sure that all glass guard connector fittings have not come 

loose after the cooling process.

DO NOT 

 lift the glass wind guard until connector fittings hardware has been checked and is still secure to the glass guards.  Glass connectors may have become 

loose after use.  Make sure all glass connectors are secure after each use of the glass wind guard.

Clean

 glass wind guards only after completely cool to the touch, approximately 45 minutes after use, with water and white vinegar mix or commercially available 

streak-free glass cleaner and a soft cloth.  

DO NOT

 touch glass wind guard for 30-45 minutes following use.  

It will be hot.

Fire Pit Base - 

Rust seepage and or oxidation may occur in some crevices.  The area can be easily serviced by using a detail brush and or fine grit sandpaper.  Once 

the are is clear from rust seepage or oxidation, follow by wiping clean and applying touch-up to seal the crevice.  Contact your local dealer for the matching touch-up 
pen or aerosol.

Hammered Copper Tops -

  Using a stainless steel polish will help protect & keep the top looking nice.  Note: Always use coasters when setting drinks and or food on 

the top.  Spilling acidic drinks and food may discolor the hand applied patina.  Should the patina be removed with acidic elements, the area will darken over time.

Porcelain Table Tops

 - Clean with mild soap and water. Rinse with clean water to remove all soap residue.  Note: The grout is made from a durable outdoor epoxy 

which does not need to be sealed.  

Page 10

Summary of Contents for CASUAL FIRESIDE Creighton 5136-42SQO

Page 1: ...ers Manual and Operating Instructions in French where you can download a copy S lectionnez le lien ci dessous pour t l charger les instructions fran aises A HIGHER STANDARD IN QUALITY AND APPEARANCE S...

Page 2: ...nces to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensi...

Page 3: ...is for outdoor use only DO NOT install or use this appliance inside a building garage or any other enclosed area or structure including recreational vehicles boats sheds This unit must be installed in...

Page 4: ...g put into operation if it is evident that the burner is damaged Replacement burner COM0590A manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible mater...

Page 5: ...building garage or other enclosed area 3 Make sure the appliance is NOT in use and turn OFF the gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is...

Page 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Page 7: ...all four sides as shown above Page 7 REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER 1 Stainless Steel X Burner 2 Propane Regulator 3 On Off Control Knob 4 Brass Control Valve 5 W...

Page 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Page 9: ...for proper air flow Note See Page 7 for Protective Screen Media Clearance CAUTION BURN HAZARD LAVA GRANULES CERAMIC LOGS and CERAMIC ROCKS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN TH...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMATION ABOVE 1 Ens...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Page 15: ...r s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un appareil surveill Les adultes doivent tre pr sents lorsque l unit est en...

Page 16: ...CE MANUEL LIQUIDATION MINIMUM DE COMBUSTIBLES Figure 1 Page 2 PUITS D INCENDIE EXTERIEUR TABLE DES MATIERES INFORMATIONS IMPORTANTES SUR LA S CURIT LIRE CES INSTRUCTIONS ENTI REMENT AVANT D INSTALLER...

Page 17: ...ajustement de l entr e est de 127 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 254 mm 10 pouces WC POUR LE PROPANE La pression minimale d admission du gaz...

Page 18: ...MENT NE PAS laisser en fonctionnement sans surveillance AVERTISSEMENT Une installation un r glage une modification un entretien ou une maintenance incorrects peuvent causer des blessures ou des dommag...

Page 19: ...le raccordement de l appareil 3 Assurez vous que l appareil n est PAS utilis et fermez le robinet de gaz au robinet d alimentation de la bouteille de gaz LP 4 La bouteille de gaz LP doit tre d branch...

Page 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Page 21: ...ection n 10 Thermocouple 10 n 11 Granules de lave n 12 Kit de verre Pebble Taille 3 4 1 2 9 19mm n 13 Trousse de vitre coupe feu concass e Taille 1 2 3 4 12 20 mm n 14 Kit de verre miroir Taille 1 4 6...

Page 22: ...s ou des dommages mat riels Laissez les granules de lave s cher compl tement apr s avoir t mouill es avant de les allumer et en utilisant le foyer Page 8 cran protecteur PLACEMENT DE SUPPORTS EN VERRE...

Page 23: ...mouill es avant de les allumer et en utilisant le foyer Page 9 PLACEMENT DE SUPPORTS DE JOURNAUX EN C RAMIQUE Placement de la roche en c ramique Voir les figures 1 2 et 3 Figure 1 Versez les granules...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: