background image

Date
Serial Number

Model #

COM0580

Work Order #

Orifice Installed 

#50 - Liquid Propane

BTU Rating

Orifice Included

NG #34 COM0580CK

Inspector

Air Shutter Sleeve

Included

Leak Test

Gas Type

Liquid Propane

Burn Test

CONVERTING YOUR FIRE PIT TO NATURAL GAS

This Conversion should only be performed by a Qualified Service Technician or Licensed Plumbe

1.

MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL 
SOURCES/APPLIANCES) ARE SHUT OFF.

2.

Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder 
from the burner pipe (Figures #1 and # 2).

3.

Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement.  
Propane requires the smaller orifice.  

4.

If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are 
closed (Figure #2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1).  After the 
unit is assembled for use, you are required to do a "leak check" by using a liquid 

soapy

 solution on all connections 

before placing the unit in operation.

5.

IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO 
CLEARLY INDICATE THE FIELD CONVERSION. 

FIGURE 1

Casual Fireside Fire Pits Are
Suitable For Installation from

0 - 4,500 ft. Without Modification.

Follow steps 1 – 5 shown above.
THE CONVERSION MUST BE CARRIED OUT 
BY A QUALIFIED SERVICE AGENCY, IN 
ACCORDANCE WITH THE REQUIREMENTS OF 
THE  MANUFACTURER, PROVINCIAL OR 
TERRITORIAL AUTHORITIES HAVING 
JURISDICTION AND IN ACCORDANCE WITH 
THE REQUIREMENTS OF THE CAN/CGA-
B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.

After conversion follow Operating Instructions 
found on Page 12.

FIGURE 2

After The Unit Is Converted, it Must Be 
Tested to Verify the Inlet and Manifold 
pressures are as specified on Page 3.  
Additionally, a qualified

 

service agency must 

verify that the input rate of the converted 
appliance match the rating listed below.

MANUFACTURER'S USE ONLY

QUALITY CHECK

LP 32,000 / NG 44,000

Page 14

Orifice

Orifice Holder

Burner

When converting to natural gas, the air shutter 
sleeve MUST be installed over the burner pipe.

Flex Line

Connector Hose

Burner

Orifice Holder

Flex Line

Connector Hose

Orifice

Air Intake hole open for LP Gas

Summary of Contents for CASUAL FIRESIDE 5110-4272D-E

Page 1: ...97 2017 CSA 2 41 2017 CGA 2 17 M91 R2017 The link below will take you to the Owners Manual and Operating Instructions in French where you can download a copy S lectionnez le lien ci dessous pour t l...

Page 2: ...9533 Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc...

Page 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Page 4: ...ut into operation if it is evident that the burner is damaged Replacement burner COM0580 manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible materials...

Page 5: ...h a cylinder connection device compatible with the connection for the appliance 3 Make sure the appliance is NOT in use and turn OFF the gas at the supply LP Gas Cylinder Valve 4 The LP Gas Cylinder m...

Page 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Page 7: ...er Quiet Flex Line 22 6 Brass Fitting 7 Propane Orifice 8 Natural Gas Conversion Kit 9 Protective Mesh Screen 10 Thermocouple 11 Electronic Igniter 12 Spark Electrode 13 Pebble Glass Kit Size 3 4 1 2...

Page 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Page 9: ...ME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW M...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMATION...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Page 15: ...ns un espace clos tel qu une caravane une tente une voiture ou la maison 4 Apr s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme...

Page 16: ...AU MOINS 60 PO DU CENTRE DU BR LEUR TOUT MURS PLAFONDS OU MAT RIAUX COMBUSTIBLES LORSQUE VOUS TEIGNEZ L APPAREIL VEILLEZ COMMANDER LA VANNE DE CONTR LE DU PUITS D INCENDIE LA POSITION TOTALE DE L ALLU...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...nstallation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr...

Page 19: ...vent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur la base inf rieure de la bouteille con ue pour permettre un retrait appropri de la...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...arche arr t n 4 Bras De Contr le Soupape n 5 Ligne Flex 22 Chuchotement Silencieux n 6 Connecteur de bouteille de propane n 7 Orifice de propane n 8 Kit de conversion de gaz propane en gaz naturel n 9...

Page 22: ...Voir les figures 1 et 2 Figure 1 Versez le premier sac du support en verre dans le support de br leur Figure 2 Versez les sacs suppl mentaires de m dia sur le support du br leur talez le support inif...

Page 23: ...TION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAINTENIR LA DISPOSITION APPROPRI E UTILISEZ LA CHALEUR GANTS R SISTANTS OU PERMETTRE AU...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ontr le du foyer ainsi que la vanne du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la...

Page 27: ...t chimique r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: