background image

INFORMATIONS SUR LE CYLINDRE DE GAZ LP (réservoir de propane):

Options de réservoir de propane de puits de feu de hauteur occasionnelle:

A) Taille du cylindre: réservoir vertical Manchester # 11

AVANT L’INSTALLATION, ASSUREZ-VOUS QUE LA SOUPAPE DU CYLINDRE DE GAZ LP-GAZ / PROPANE EST FERMÉE.

Réservoir de 20 livres

Réservoir de 11 livres

B) Taille du cylindre: Manchester Tank # 20
20 lb (9.07 kg) Capacité: 4,6 gallons (17,41 litres).

CONNEXION D'UN RESERVOIR DE PROPANE AU CYLINDRE DE GAZ LP

IMPORTANT

AVANT DE PROCÉDER, LISEZ ATTENTIVEMENT TOUT L'IMPORTANT

INFORMATIONS DE SÉCURITÉ DANS CE MANUEL D'UTILISATEUR

A.

AVERTISSEMENTS IMPORTANTS ET CONSIGNES DE SÉCURITÉ (Pages 1, 2, 3, 4)

B.

Dégagement minimum aux combustibles (page 2)

1.

2.

La ou les bouteilles de gaz LP à utiliser doivent être construites et marquées conformément aux directives du département américain de la 
Transport (D.O.T.) Spécifications des bouteilles de gaz LP ou norme sur les bouteilles, sphères et tubes pour le transport des marchandises 
dangereuses et Commission, CAN / CSA-B339, selon le cas.
- Utilisez des bouteilles agréées pour votre région, telles que «Blue Rhino» ou «AmeriGas» avec cet appareil. D'autres bouteilles peuvent être 
acceptées pour une utilisation avec l'appareil à condition qu'elles puissent être montées sur l'appareil à l'aide du dispositif de retenue de bouteille 
fourni. (Voir l'illustration ci-dessus.)
--La   bouteille de gaz LP à utiliser doit être munie d'un dispositif de prévention de trop-plein (OPD) répertorié et d'un dispositif de connexion de 
bouteille compatible avec le raccordement de l'appareil.

3.

Assurez-vous que l'appareil n'est PAS utilisé et fermez le robinet de gaz au robinet d'alimentation de la bouteille de gaz LP.

4.

La bouteille de gaz LP doit être débranchée lorsque l'appareil n'est pas utilisé.

11 lb (4 kg) Capacité: 2,6 gallons (9,84 litres).

Lors du raccordement du régulateur à la vanne du réservoir, assurez-vous que l'écrou d'accouplement ne fait pas de filetage croisé sur la 
vanne du réservoir.  Le filetage croisé de l'écrou du régulateur sur la vanne du réservoir peut provoquer une fuite.
Allumez le gaz au système de brûleur et testez les fuites avec une solution d'eau savonneuse.
(Ne jamais utiliser une flamme nue pour les tests). Si une fuite est détectée, reconnectez l'écrou-raccord du régulateur et serrez jusqu'à ce 
qu'aucune fuite ne soit détectée. Le tuyau et le brûleur doivent être inspectés avant chaque utilisation de l'appareil.
Le tuyau doit être remplacé avant la mise en service de l'appareil en cas d'abrasion ou d'usure excessive, ou si le tuyau est endommagé. Le 
tuyau de remplacement doit être spécifié par le fabricant.

Page 5

5.

Les bouteilles de gaz LP doivent être entreposées à l'extérieur dans un endroit bien ventilé, hors de la portée des enfants et à une distance d'au 
moins 60 pouces du foyer. Les capuchons de vanne filetés doivent être bien installés dans les bouteilles déconnectées et ne doivent pas être 
entreposés dans un bâtiment, un garage ou un autre espace clos.

6.

La bouteille de gaz GPL doit reposer sur la base inférieure de la bouteille conçue pour permettre un retrait approprié de la vapeur.

Summary of Contents for CASUAL FIRESIDE 5110-2442O

Page 1: ...r Propane Storage and Handling Code B149 2 as applicable READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT If the information in this manual is not followed exactly a fire or explo...

Page 2: ...THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY O...

Page 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Page 4: ...ar the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any g...

Page 5: ...rfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 2 Occasional Height Fire Pits Propane Tank Options CONNECTING AN LP GAS CYLINDER P...

Page 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Page 7: ...ss Kit Size 3 4 1 2 9 19mm 12 Crushed Fire Glass Kit Size 1 2 3 4 12 20 mm 13 Mirrored Glass Kit Size 1 4 6 35mm 14 Lava Granules 3 8 PROTECTIVE SCREEN MEDIA PLACEMENT Media placement is crucial to th...

Page 8: ...IN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING CAUTION Lava granules used in a fire pit are porous and when heated up to normal operating temper...

Page 9: ...launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lighting and using the fire pit Page 9...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...k valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve layou...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Page 15: ...dans un espace clos tel qu une caravane une tente une voiture ou la maison 4 Apr s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u com...

Page 16: ...NUEL LIQUIDATION MINIMUM DE COMBUSTIBLES Figure 1 Page 2 PUITS D INCENDIE EXTERIEUR TABLE DES MATIERES INFORMATIONS IMPORTANTES SUR LA S CURIT LIRE CES INSTRUCTIONS ENTI REMENT AVANT D INSTALLER CE FO...

Page 17: ...ajustement de l entr e est de 127 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 254 mm 10 pouces WC POUR LE PROPANE La pression minimale d admission du gaz...

Page 18: ...ISSEMENT NE PAS laisser en fonctionnement sans surveillance AVERTISSEMENT Une installation un r glage une modification un entretien ou une maintenance incorrects peuvent causer des blessures ou des do...

Page 19: ...op plein OPD r pertori et d un dispositif de connexion de bouteille compatible avec le raccordement de l appareil 3 Assurez vous que l appareil n est PAS utilis et fermez le robinet de gaz au robinet...

Page 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Page 21: ...n 8 Kit de conversion au gaz naturel n 9 cran de protection 09 n 10 Thermocouple 10 n 11 Ensemble de verres galets Taille 3 4 1 2 9 19mm n 12 Ensemble de vitre coupe feu n Taille 1 2 3 4 12 20 mm n 13...

Page 22: ...igure 1 Versez le premier sac du support en verre dans le support de br leur cran protecteur Figure 2 Versez les sacs suppl mentaires de m dia sur le support du br leur talez le support iniform ment e...

Page 23: ...un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAINTENIR LA DISPOSITI...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...l appareil et pour remplacer toute pi ce du syst me de contr le et tout contr le de gaz qui aurait t sous l eau INSTRUCTIONS D CLAIRAGE STOP LIRE LES INFORMATIONS DE S CURIT CI DESSUS 1 Assurez vous q...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: