IMPORTANT:  If the old unit didn’t power down with the 
shuttle parked, contact Overland Technical Support.

Secure the Robotics

CAUTION:  

Units that do not have the four holes 

underneath for the well nuts and screws must use the 
enclosed Wire Tie-Down kit to secure the robotics before 
packaging the unit.

For units with the four holes, follow this procedure:

1.

Attach the 

old drive cover

 to the old chassis.

2.

Open the 

left door

.

3.

Install the 

shuttle bracket

:

a.

Holding the shuttle bracket by the 

front lip

 

(

Figure 3

), slide it into the magazine bay.

Figure 3.  Inserting the Shuttle Bracket

b. Swing the rear

 of the bracket to the

 right 

until it 

contacts the shuttle.

c.

Press the 

front lip

 of the bracket down and to the 

right until the screw holes align.
You should hear a click as the bracket slips into 
place over the shuttle.

d.

Install the 

screw

 that holds the shuttle bracket to 

the bottom edge of the front panel.

4.

Turn the unit onto its 

left side

 with the 

front bezel 

off the table

5.

Install the 

shuttle bracket well nut

:

a.

With a 

washer

 on a 

screw

, screw it onto a 

well nut

 

until only one-half inch (12.5cm) remains extended.

b.

Repeat 

Step a

 for the other 

three

 well nuts.

c.

While pressing the 

shuttle bracket

 down, visually 

confirm the 

hole alignment

 from underneath.

d.

Insert a 

well nut assembly 

(

Figure 4

) through the 

three holes using the extended screw as a handle.

Figure 4.  Well Nut Insertion (Side View)

e.

While continuing to hold the bracket against the 
shuttle, tighten the 

screw

 into the well nut.

6.

Insert the remaining 

three well nut assemblies

 

using the extended screws, and tighten (

Figure 5

).

Figure 5.  Installing the Well Nuts and Screws

7.

Carefully return the 

library

 to the upright position.

Repack the Chassis

Once the robotics are secure, repack the unit for shipment.

1.

Open the top of the box and remove all the 

packaging 

materials

 stored there.

2.

With the ARCvault

 

on a secure surface, slide it into the 

ESD bag

 and seal with packing tape.

3.

Attach the 

larger end caps

 to the rear.

4.

Attach the 

smaller end caps

 to the front.

5.

Using two people, lower the 

ARCvault 

into the box.

6.

Tape the box

 using the type of tape required by the 

shipper for the shipping method being used.

All information contained in or disclosed by this document is considered proprietary by Overland Storage. By accepting this material, the recipient agrees that this material and the information contained therein are held in confidence and in trust and will not be

used, reproduced in whole or in part, nor its contents revealed to others, except to meet the purpose for which it was delivered. It is understood that no right is conveyed to reproduce or have reproduced any item herein disclosed without express permission from

Overland Storage. Overland Storage provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Overland Storage may make

improvements or changes in the product(s) or program(s) described in this document at any time. These changes will be incorporated in new editions of this publication.
Overland Storage assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of this document, nor for any problem that might arise from the use of the information in this document.

Repackaging the Library

Bracket Front Lip

Well Nut

Bracket

Track Plate

Chassis

Correct

Incorrect

Shuttle

Stop Washer

A

RC

-0

04

8

Screws & Well Nuts

Shuttle Bracket Hole

Additional Help

You can get additional technical support on the Internet at http://support.overlandstorage.com, or call 

1-877-654-3429 (toll-free U.S. & Canada), +44 (0) 118-9898050 (Europe), or +1 (858) 571-5555 Option 5 (International).