29
|
Legend:
Symbol
Specification
x
Channel is available
x*
Channel is available if the corresponding option is activated.
Adjustment Channels
Channel
Description
Factory setting
Page
DT O
x
Switch-on temperature difference
6.0 K [12.0 °Ra]
57
DT F
x
Switch-off temperature difference
4.0 K [8.0 °Ra]
57
DT S
x
Nominal temperature difference
10.0 K [20.0 °Ra]
57
RIS
x
Rise control
2 K [4 °Ra]
57
nMN
x
Minimum pump speed
30 %
57
S MX
x
Maximum store temperature
60 °C [140 °F]
58
OSEM
x
Option store emergency shutdown
OFF
58
EM
x
Emergency temperature collector
130 °C [270 °F]
58
Emergency temperature collector if ODB is activated:
95 °C [200 °F]
58
OCC
x
Option collector cooling
OFF
59
CMX
x*
Maximum collector temperature
110 °C [230 °F]
59
OSYC
x
Option system cooling
OFF
59
DTCO
x*
Cooling switch-on temperature difference
20.0 K [40.0 °Ra]
59
DTCF
x*
Cooling switch-off temperature difference
15.0 K [30.0 °Ra]
59
OSTC
x
Option store cooling
OFF
60
OHOL
x*
Option holiday cooling
OFF
60
THOL
x*
Holiday cooling temperature
40 °C [110 °F]
60
OCN
x
Option minimum limitation
OFF
60
CMN
x*
Minimum collector temperature
10 °C [50 °F]
60
OCF
x
Option antifreeze
OFF
60
CFR
x*
Antifreeze temperature
4.0 °C [40.0 °F]
60
OHQM
x
Option heat quantity measurement
OFF
61
FMAX
x*
Maximum flow
6.0 l
61
MEDT
x*
Antifreeze type
1
61
MED%
x*
Antifreeze concentration (only if MEDT = propylene or ethylene)
45 %
61
ODB
x
Drainback option
OFF
61
tDTO
x*
ODB switch-on condition - time period
60 s
61
tFLL
x*
ODB filling time
5.0 min
62
tSTB
x*
ODB stabilisation time
2.0 min
62
MAN1
x
Manual operation R1
Auto
62
ADA1
x
HE pump control
OFF
62
LANG
x
Language
En
62
UNIT
x
Temperature unit
°C
62
RESE
x
Reset - back to factory settings
62
W002####
Version number
Summary of Contents for Regtronic BS/2-B
Page 1: ...49013741 49013741 Premium Armaturen Systeme Regtronic BS 2 B Montage und Bedienungsanleitung...
Page 23: ...Valves controls systems Regtronic BS 2 B Installation and operating instructions...
Page 45: ...Robinetterie haut de gamme Syst mes Regtronic BS 2 B Notice d installation et d utilisation...
Page 66: ...66...
Page 67: ...67...