ClimaCon F
Safety-related information
2. Safety-related information
2.1 Correct use
Operational safety is only guaranteed if the product is
used as intended.
The ClimaCon F room thermostats are electronically
controlled operating devices for controlling surface
heating and cooling systems as well as heating and
cooling ceilings in detached houses or multiple dwellings.
Any use beyond and/or different from this is unintended
use.
Claims of any kind against the manufacturer and/or his
authorised representatives for damage resulting from
unintended use cannot be recognised.
Intended use also includes correct compliance with these
instructions.
2.2 Warnings
Each warning contains the following elements:
Warning symbol
SIGNAL WORD
Type and source of danger!
Possible consequences if the danger occurs or the
warning is ignored.
!
Ways to avoid the danger.
Signal words define the severity of the danger posed by a
situation.
WARNING
Indicates a possible danger with moderate risk. If the
situation is not avoided, death or serious bodily injuries
may result.
CAUTION
Indicates a possible danger with lower risk. If the
situation is not avoided, minor and reversible bodily
injuries will result.
NOTICE
Indicates a situation that can potentially result in damage
to property if not avoided.
2.3 Safety instructions
We have developed this product in accordance with
current safety requirements.
Observe the following instructions for safe use.
2.3.1 Danger
due to electric current
!
Make sure that the product can be disconnected
from the power supply at any time.
!
(
ClimaCon 230 V only
) The power supply you use
must meet the criteria of overvoltage categories
I or II according to DIN EN 60664-1. At the
installation site, observe any additional applicable
legal requirements derived from the IEC 60364 or
HD 60364.
!
Do not operate the product if there is visible
damage.
!
Work on the power supply may only be carried
out by a specialist electrician.
!
Disconnect the product from the power supply
at all poles for installation work, secure it against
being switched on again and check that no
voltage is present.
!
Only install the product in dry indoor areas.
!
For devices with a 24 V power supply, use a SELV
voltage source that is galvanically isolated from
the earth potential.
!
The setback input (ClimaCon F 90, F 100;
terminal 4) and the change-over input (ClimaCon
F 100, F 310; terminal 5) are not potential-
free. Avoid direct contact. Do not connect any
equipment here that could be damaged by
electrical potentials or whose function could be
disturbed.
2.3.2 Danger due to insufficient personnel
qualification
Work on this product may only be carried out by suitably
qualified specialist tradespeople.
Due to their professional training and experience as well
as knowledge of the relevant legal regulations, qualified
specialist tradespeople are able to carry out work on the
described product in a professional manner.
Operator
The operator must be instructed in the operation by
specialist tradespeople.
2.3.3 Availability of the operating instructions
Every person who works with this product must have read
and apply this manual and all applicable instructions.
The instructions must be available at the place of use of
the product.
!
Pass on these instructions and all applicable
instructions to the operator.